ActiGraph and Actical physical activity monitors: a peek under the hood
- PMID: 22157779
- PMCID: PMC3248573
- DOI: 10.1249/MSS.0b013e3182399f5e
ActiGraph and Actical physical activity monitors: a peek under the hood
Abstract
Since the 1980s, accelerometer-based activity monitors have been used by researchers to quantify physical activity. The technology of these monitors has continuously evolved. For example, changes have been made to monitor hardware (type of sensor (e.g., piezoelectric, piezoresistive, capacitive)) and output format (counts vs raw signal). Commonly used activity monitors belong to the ActiGraph and the Actical families. This article presents information on several electromechanical aspects of these commonly used activity monitors. The majority of the article focuses on the evolution of the ActiGraph activity monitor by describing the differences among the 7164, the GT1M, and the GT3X models. This is followed by brief descriptions of the influences of device firmware and monitor calibration status. We also describe the Actical, but the discussion is short because this device has not undergone any major changes since it was first introduced. This article may help researchers gain a better understanding of the functioning of activity monitors. For example, a common misconception among physical activity researchers is that the ActiGraph GT1M and GT3X are piezoelectric sensor-based monitors. Thus, this information may also help researchers to describe these monitors more accurately in scientific publications.
References
-
- Cavagna G, Saibene F, Margaria R. A three-directional accelerometer for analyzing body movements. J Appl Physiol. 1961;16:191. - PubMed
-
- Karcher J. A piezo electric method for the instantaneous measurement of high pressures. Journal of the Franklin Institute. 1922;194(6):815–6.
-
- Walter P. The history of the accelerometer. Sound and Vibration. 1997;31(3):16–23.
-
- Wong TC, Webster JG, Montoye HJ, Washburn R. Portable accelerometer device for measuring human energy expenditure. IEEE Trans Biomed Eng. 1981;28(6):467–71. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources