What is the optimum antibiotic prophylaxis in patients undergoing implantation of a left ventricular assist device?
- PMID: 22159247
- PMCID: PMC3279966
- DOI: 10.1093/icvts/ivr054
What is the optimum antibiotic prophylaxis in patients undergoing implantation of a left ventricular assist device?
Abstract
A best evidence topic was written according to a structured protocol. The question addressed was what the optimum antibiotic prophylaxis in patients undergoing implantation of a left ventricular assist device (LVAD) is. A total of 373 papers were found, of which 11 represented the best evidence. The authors, date, journal, study type, population, main outcome measures and results are tabulated. Eight retrospective and two prospective studies, including one randomized controlled trial (RCT), were identified. Although highly variable, the prophylactic antibiotic protocols employed in these studies generally favour the use of vancomycin, a cephalosporin, beta-lactam and quinolone, with the option of additional fluconazole and mupirocin. However, the lack of standardized definitions for infection, and variations in the choice, timing and duration of prophylactic antibiotics complicates the interpretation of reported infection rates. Driveline and pocket infections comprised the majority of infectious complications, and were principally attributed to Gram-positive organisms, such as Staphylococcus, as well as Pseudomonas species. We conclude that a beta-lactam be used for primary prophylaxis, with vancomycin where the risk of MRSA is high. Topical mupirocin and an anti-fungal are also recommended. Prophylaxis should commence prior to device insertion, and be continued into the peri- and post-operative period. Large-scale RCTs are necessary to assess the impact of different antibiotic regimens on infection within LVAD recipients.
References
-
- Dunning J, Prendergast B, Mackway-Jones K. Towards evidence-based medicine in cardiothoracic surgery: best BETS. Interact CardioVasc Thorac Surg. 2003;2:405–9. - PubMed
-
- Topkara VK, Kondareddy S, Malik F, Wang IW, Mann DL, Ewald GA, et al. Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era. Ann Thorac Surg. 2010;90:1270–7. - PubMed
-
- Simon D, Fischer S, Grossman A, Downer C, Hota B, Heroux A, et al. Left ventricular assist-device related infection: treatment and outcome. Clin Infect Dis. 2005;40:1108–15. - PubMed
-
- Holman WL, Park SJ, Long JW, Weinberg A, Gupta L, Tierney AR, et al. REMATCH Investigators. Infection in permanent circulatory support: experience from the REMATCH trial. J Heart Lung Transplant. 2004;23:1359–65. - PubMed
-
- Herrmann M, Weyand M, Greshake B, von Eiff C, Proctor RA, Scheld HH, et al. Left ventricular assist device infection is associated with increased mortality but is not a contraindication to transplantation. Circulation. 1997;95:814–7. - PubMed