Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study
- PMID: 22182495
- DOI: 10.1016/j.hrthm.2011.12.014
Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study
Abstract
Background: Today quantitative information about the type of complications and their incidence during long-term pacemaker (PM) follow-up is scarce.
Objective: To assess the incidence and determinants of short- and long-term complications after first pacemaker implantation for bradycardia.
Methods: A prospective multicenter cohort study (the FOLLOWPACE study) was conducted among 1517 patients receiving a PM between January 2003 and November 2007. The independent association of patient and implantation-procedure characteristics with the incidence of PM complications was analyzed using multivariable Cox regression analysis.
Results: A total of 1517 patients in 23 Dutch PM centers were followed for a mean of 5.8 years (SD 1.1), resulting in 8797 patient-years. Within 2 months, 188 (12.4%) patients developed PM complications. Male gender, age at implantation, body mass index, a history of cerebrovascular accident, congestive heart failure, use of anticoagulant drugs, and passive atrial lead fixation were independent predictors for complications within 2 months, yielding a C-index of 0.62 (95% confidence interval 0.57-0.66). Annual hospital implanting volume did not additionally contribute to the prediction of short-term complications. Thereafter, 140 (9.2%) patients experienced complications, mostly lead-related complications (n = 84). Independent predictors for long-term complications were age, body mass index, hypertension, and a dual-chamber device, yielding a C-index of 0.62 (95% confidence interval 0.57-0.67). The occurrence of a short-term PM complication was not predictive of future PM complications.
Conclusions: Complication incidence in modern pacing therapy is still substantial. Most complications occur early after PM implantation. Although various patient- and procedure-related characteristics are independent predictors for early and late complications, their ability to identify the patient at high risk is rather poor. This relatively high incidence of PM complications and their poor prediction underscores the usefulness of current guidelines for regular follow-up of patients with PM.
Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Incidence and predictors of pacemaker reprogramming: potential consequences for remote follow-up.Europace. 2013 Jul;15(7):978-83. doi: 10.1093/europace/eut002. Epub 2013 Feb 17. Europace. 2013. PMID: 23419656
-
Incidence and predictors of in-hospital events after first implantation of pacemakers.Europace. 2007 Oct;9(10):884-9. doi: 10.1093/europace/eum113. Epub 2007 Jun 7. Europace. 2007. PMID: 17556376
-
Prognosis of the bradycardia pacemaker recipient assessed at first implantation: a nationwide cohort study.Heart. 2013 Nov;99(21):1573-8. doi: 10.1136/heartjnl-2013-304445. Epub 2013 Aug 22. Heart. 2013. PMID: 23969476
-
FOLLOWPACE study: a prospective study on the cost-effectiveness of routine follow-up visits in patients with a pacemaker.Europace. 2006 Jan;8(1):60-4. doi: 10.1093/europace/euj005. Europace. 2006. PMID: 16627411
-
Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature.J Cardiovasc Electrophysiol. 2012 Apr;23(4):391-7. doi: 10.1111/j.1540-8167.2011.02211.x. Epub 2011 Nov 3. J Cardiovasc Electrophysiol. 2012. PMID: 22050112 Review.
Cited by
-
Leadless cardiac pacing.Indian Pacing Electrophysiol J. 2016 Mar-Apr;16(2):80-81. doi: 10.1016/j.ipej.2016.08.009. Epub 2016 Aug 26. Indian Pacing Electrophysiol J. 2016. PMID: 27676167 Free PMC article. No abstract available.
-
Syncope after successful implantation of atrioventricular synchronous leadless pacemaker caused by polymorphic ventricular tachycardia.HeartRhythm Case Rep. 2020 May 18;6(8):503-506. doi: 10.1016/j.hrcr.2020.05.003. eCollection 2020 Aug. HeartRhythm Case Rep. 2020. PMID: 32817828 Free PMC article. No abstract available.
-
Initial experience with a leadless pacemaker (Micra™) implantation in a low volume center in South East Asia.Future Cardiol. 2018 Sep;14(5):389-395. doi: 10.2217/fca-2017-0106. Epub 2018 Sep 25. Future Cardiol. 2018. PMID: 30251546 Free PMC article.
-
Postural Conversion Computed Tomography for the Diagnosis of Pneumopericardium due to Perforation by the Active Atrial Lead.Intern Med. 2020 Feb 15;59(4):541-544. doi: 10.2169/internalmedicine.3729-19. Epub 2019 Oct 24. Intern Med. 2020. PMID: 31645534 Free PMC article.
-
The modular cardiac rhythm management system: the EMPOWER leadless pacemaker and the EMBLEM subcutaneous ICD.Herzschrittmacherther Elektrophysiol. 2018 Dec;29(4):355-361. doi: 10.1007/s00399-018-0602-y. Epub 2018 Oct 31. Herzschrittmacherther Elektrophysiol. 2018. PMID: 30382341 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical