Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Sep;45(9):684-7.
doi: 10.1136/thx.45.9.684.

Plasma cross linked fibrin degradation products in pulmonary embolism

Affiliations

Plasma cross linked fibrin degradation products in pulmonary embolism

B J Rowbotham et al. Thorax. 1990 Sep.

Abstract

Plasma concentrations of cross linked fibrin degradation products, a marker of intravascular thrombosis and fibrinolysis, were measured in 495 patients with suspected pulmonary embolism referred for ventilation-perfusion lung scanning to determine whether concentrations are increased in pulmonary embolism and their potential use in diagnosis. Lung scans were described as normal (n = 66) or as showing a low (n = 292), indeterminate (n = 58), or high probability (n = 79) of pulmonary embolism. There was a difference between the mean levels of cross linked fibrin degradation products in each scan category: normal scans, 142 ng/ml; low probability scans, 295 ng/ml; indeterminate probability scans, 510 ng/ml; high probability scans, 952 ng/ml (p less than 0.001). Of the patients with high probability scans, 96% had raised concentrations. Explanations for discrepant low results include incorrect scan diagnosis, delay in blood sampling, and anticoagulation. Of the patients with a low or indeterminate probability of pulmonary embolism, 43% had increased concentrations of cross linked fibrin degradation products that could be attributed in most cases to another illness. Owing to the wide range of values in each lung scan diagnostic category, raised concentrations of these fibrin degradation products cannot be used without reference to the patient's clinical state as a discriminatory test for pulmonary embolism. Further evaluation of the significance of normal concentrations in excluding a diagnosis of pulmonary embolism appears to be warranted.

PubMed Disclaimer

References

    1. Am J Cardiol. 1967 Sep;20(3):374-80 - PubMed
    1. Lancet. 1988 Sep 10;2(8611):628-9 - PubMed
    1. Ann Intern Med. 1973 Nov;79(5):664-8 - PubMed
    1. Blood. 1975 Apr;45(4):563-8 - PubMed
    1. Blood. 1978 Jun;51(6):1189-95 - PubMed

Substances