Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Mar;31(3):777-89.
doi: 10.1109/TMI.2011.2180920. Epub 2011 Dec 23.

Hierarchical scale-based multiobject recognition of 3-D anatomical structures

Affiliations

Hierarchical scale-based multiobject recognition of 3-D anatomical structures

Ulas Bagci et al. IEEE Trans Med Imaging. 2012 Mar.

Abstract

Segmentation of anatomical structures from medical images is a challenging problem, which depends on the accurate recognition (localization) of anatomical structures prior to delineation. This study generalizes anatomy segmentation problem via attacking two major challenges: 1) automatically locating anatomical structures without doing search or optimization, and 2) automatically delineating the anatomical structures based on the located model assembly. For 1), we propose intensity weighted ball-scale object extraction concept to build a hierarchical transfer function from image space to object (shape) space such that anatomical structures in 3-D medical images can be recognized without the need to perform search or optimization. For 2), we integrate the graph-cut (GC) segmentation algorithm with prior shape model. This integrated segmentation framework is evaluated on clinical 3-D images consisting of a set of 20 abdominal CT scans. In addition, we use a set of 11 foot MR images to test the generalizability of our method to the different imaging modalities as well as robustness and accuracy of the proposed methodology. Since MR image intensities do not possess a tissue specific numeric meaning, we also explore the effects of intensity nonstandardness on anatomical object recognition. Experimental results indicate that: 1) effective recognition can make the delineation more accurate; 2) incorporating a large number of anatomical structures via a model assembly in the shape model improves the recognition and delineation accuracy dramatically; 3) ball-scale yields useful information about the relationship between the objects and the image; 4) intensity variation among scenes in an ensemble degrades object recognition performance.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources