Tight glucose control (TGC) in critical care settings is becoming increasingly the standard of care. However, TGC comes with the risk of hypoglycemia, as highlighted by some recent studies. Our aim was to establish TGC in burn patients without increasing rates of hypoglycemia. The authors used a computer-driven glucose control program (CGS) to achieve this goal. The computer program calculates insulin drip rates by using a multiplier that changes according to blood glucose (BG) values as well as trends and keeps a record of BG data and insulin infusion rates for future quality control analysis. CGS is also a useful adjunct in transitioning patients from an IV insulin drip to subcutaneous insulin. A retrospective review of the glucose control program database was performed to obtain information on length of time to goal glucose levels (set at 100-150 mg/dl), glucose level trends, and incidence of hypoglycemia when using the computer program. Over 18 months, we used CGS on 94 critical and noncritical burn patients. Mean time to target BG was 5.1 hours. Glucose levels of 100 to 150 mg/dl were maintained 63.3% of the time, and values within the wider range of 70 to 150 mg/dl were maintained 80.8% of the time. The incidence of hypoglycemia, defined as BG level below 70 mg/dl, was only 1.66% and was treated without any adverse sequelae. Hyperglycemic episodes were directly correlated with surgical interventions during which time the CGS was not utilized in the operating room. CGS offers a safe and effective means of rapidly achieving and maintaining glucose targets in burn patients. Further analysis of the data needs to be conducted to determine whether the BG targets used in our study offer a morbidity benefit to burn patients.
Similar articles
-
Computerized insulin infusion programs are safe and effective in the burn intensive care unit.J Burn Care Res. 2012 May-Jun;33(3):e114-9. doi: 10.1097/BCR.0b013e3182331e39. J Burn Care Res. 2012. PMID: 22079904
-
Utilization of a computerized intravenous insulin infusion program to control blood glucose in the intensive care unit.Diabetes Technol Ther. 2007 Jun;9(3):232-40. doi: 10.1089/dia.2006.0015. Diabetes Technol Ther. 2007. PMID: 17561793
-
Minimization of Hypoglycemia as an Adverse Event During Insulin Infusion: Further Refinement of the Yale Protocol.Diabetes Technol Ther. 2016 Aug;18(8):480-6. doi: 10.1089/dia.2016.0101. Epub 2016 Jun 3. Diabetes Technol Ther. 2016. PMID: 27257910 Free PMC article.
-
Perioperative control of blood glucose level in cardiac surgery.Gen Thorac Cardiovasc Surg. 2013 Feb;61(2):61-6. doi: 10.1007/s11748-012-0198-9. Epub 2013 Jan 5. Gen Thorac Cardiovasc Surg. 2013. PMID: 23292688 Review.
-
Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients.Crit Care Med. 2012 Dec;40(12):3251-76. doi: 10.1097/CCM.0b013e3182653269. Crit Care Med. 2012. PMID: 23164767 Review.