Validation of tonometric measurement of gut intramural pH during endotoxemia and mesenteric occlusion in pigs

Affiliations

Validation of tonometric measurement of gut intramural pH during endotoxemia and mesenteric occlusion in pigs

J B Antonsson et al. Am J Physiol. 1990 Oct.

Abstract

Tonometry is a minimally invasive method for estimating gastrointestinal intramural pH (pHi). Tissue pH is calculated by using the Henderson-Hasselbalch equation and measurements of arterial [HCO-3] and CO2 tension (PCO3) of saline contained in a Silastic balloon within the lumen of the gut. The validity of the method rests on two key assumptions: 1) PCO2 in saline in the tonometer balloon is similar to tissue PCO2 and 2) tissue and arterial [HCO-3] are similar. To validate this method, ileal pHi measured directly with a microelectrode was compared with pHi estimated tonometrically in four groups of anesthetized pigs. Group I (n = 4) were controls. In group II (n = 4), intestinal tissue acidosis was induced by total occlusion of the superior mesenteric artery (SMA). In group III (n = 5), acidosis was induced by partial occlusion of the SMA. In group IV (n = 4), tissue acidosis was induced by endotoxemia. Agreement was excellent between direct and tonometric measurements in groups I and IV and less good in groups II and III. Weighted mean correlation coefficients (rw) for the two measurement methods were 0.743 and 0.9447 in groups II and IV, respectively. Correlation coefficients for the individual animals in group III were more variable than the other groups and ranged from 0.547 to 0.990. The tonometric method for measuring GI pHi is invalid under conditions of zero flow and leads to error under conditions of low flow. However, the method is reliable in the setting of tissue acidosis induced by endotoxemia.