Swan-Ganz catheter-induced massive hemoptysis and pulmonary artery false aneurysm
- PMID: 2222056
- DOI: 10.1016/0003-4975(90)90206-l
Swan-Ganz catheter-induced massive hemoptysis and pulmonary artery false aneurysm
Abstract
Swan-Ganz catheter-induced massive hemoptysis and later pulmonary artery false aneurysm occurred in a patient with prosthetic mitral regurgitation. This patient was successfully managed by double-lumen endotracheal intubation, control of pulmonary hypertension, reversal of anticoagulation, mitral valve re-replacement, and transcatheter embolization. The pertinent literature is reviewed.
Similar articles
-
False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: clinical presentation and radiologic management.AJR Am J Roentgenol. 1996 Oct;167(4):941-5. doi: 10.2214/ajr.167.4.8819388. AJR Am J Roentgenol. 1996. PMID: 8819388
-
Massive hemoptysis after coronary artery bypass grafting.Chest. 1996 Jan;109(1):267-70. doi: 10.1378/chest.109.1.267. Chest. 1996. PMID: 8549196 No abstract available.
-
Nominal hemoptysis heralds pseudoaneurysm induced by a pulmonary artery catheter.Anesthesiology. 1991 Feb;74(2):370-3. doi: 10.1097/00000542-199102000-00028. Anesthesiology. 1991. PMID: 1990914 No abstract available.
-
Pulmonary artery pseudoaneurysm after Swan-Ganz catheterization: a case presentation and review of literature.Eur Heart J Acute Cardiovasc Care. 2014 Sep;3(3):281-8. doi: 10.1177/2048872613520252. Epub 2014 Jan 27. Eur Heart J Acute Cardiovasc Care. 2014. PMID: 24470440 Review.
-
Swan-Ganz catheter induced pulmonary artery perforation during cardiac surgery concerning two cases.J Cardiovasc Surg (Torino). 1996 Jun;37(3):313-7. J Cardiovasc Surg (Torino). 1996. PMID: 8698771 Review.
Cited by
-
Catheter-induced pulmonary artery rupture: haemodynamic compromise necessitates surgical repair.Interact Cardiovasc Thorac Surg. 2012 Sep;15(3):531-3. doi: 10.1093/icvts/ivs287. Epub 2012 Jun 20. Interact Cardiovasc Thorac Surg. 2012. PMID: 22718463 Free PMC article.
-
Real or apparent entrapment of a Swan-Ganz pulmonary artery catheter after cardiac surgery?Intensive Care Med. 1994;20(4):309-10. doi: 10.1007/BF01708978. Intensive Care Med. 1994. PMID: 8046132 No abstract available.
-
Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report.Korean J Anesthesiol. 2014 Nov;67(5):346-9. doi: 10.4097/kjae.2014.67.5.346. Epub 2014 Nov 26. Korean J Anesthesiol. 2014. PMID: 25473465 Free PMC article.
-
The pulmonary artery catheter: When and why it should be used.Can J Anaesth. 1992 May;39(Suppl 1):R71-9. doi: 10.1007/BF03008845. Can J Anaesth. 1992. PMID: 27518649 English. No abstract available.
-
A preliminary study on the monitoring of mixed venous oxygen saturation through the left main bronchus.Crit Care. 2006 Feb;10(1):R7. doi: 10.1186/cc3914. Crit Care. 2006. PMID: 16356208 Free PMC article.