Automated localisation and boundary identification of superficial femoral artery on MRI sequences
- PMID: 22220925
- DOI: 10.1080/10255842.2011.643468
Automated localisation and boundary identification of superficial femoral artery on MRI sequences
Abstract
In this paper, an automated method to localise the right superficial femoral artery (SFA) and identify its boundary on magnetic resonance imaging (MRI) sequences without contrast medium injection is proposed. Some anatomical knowledge combined with the mathematical morphology is used to distinguish SFA from other vessels. Afterwards, the directional gradient, continuity and the local contrast are applied as features to identify the artery's boundary using dynamic programming. The accuracy analysis shows that the system has average unsigned errors 3.1 ± 3.1% on five sequences compared to experts' manual tracings.
Similar articles
-
Three-dimensional expansion of a dynamic programming method for boundary detection and its application to sequential magnetic resonance imaging (MRI).Sensors (Basel). 2012;12(5):5195-211. doi: 10.3390/s120505195. Epub 2012 Apr 26. Sensors (Basel). 2012. PMID: 22778580 Free PMC article.
-
Accurate Measurement of Cross-Sectional Area of Femoral Artery on MRI Sequences of Transcontinental Ultramarathon Runners Using Optimal Parameters Selection.J Med Syst. 2016 Dec;40(12):260. doi: 10.1007/s10916-016-0626-y. Epub 2016 Oct 8. J Med Syst. 2016. PMID: 27722979
-
Automatic detection of the carotid artery boundary on cross-sectional MR image sequences using a circle model guided dynamic programming.Biomed Eng Online. 2011 Apr 11;10:26. doi: 10.1186/1475-925X-10-26. Biomed Eng Online. 2011. PMID: 21477378 Free PMC article.
-
The origin of the medial femoral circumflex artery, lateral femoral circumflex artery and obturator artery.Surg Radiol Anat. 2018 May;40(5):515-520. doi: 10.1007/s00276-018-2012-6. Epub 2018 Apr 12. Surg Radiol Anat. 2018. PMID: 29651567 Free PMC article. Review.
-
[Justification for stents in the femoral artery: a surgical point of view].Hamostaseologie. 2003 May;23(2):90-6. Hamostaseologie. 2003. PMID: 12736705 Review. German.
Cited by
-
Three-dimensional expansion of a dynamic programming method for boundary detection and its application to sequential magnetic resonance imaging (MRI).Sensors (Basel). 2012;12(5):5195-211. doi: 10.3390/s120505195. Epub 2012 Apr 26. Sensors (Basel). 2012. PMID: 22778580 Free PMC article.
-
Accurate Measurement of Cross-Sectional Area of Femoral Artery on MRI Sequences of Transcontinental Ultramarathon Runners Using Optimal Parameters Selection.J Med Syst. 2016 Dec;40(12):260. doi: 10.1007/s10916-016-0626-y. Epub 2016 Oct 8. J Med Syst. 2016. PMID: 27722979
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical