Counting Legionella cells within single amoeba host cells
- PMID: 22226955
- PMCID: PMC3298162
- DOI: 10.1128/AEM.07392-11
Counting Legionella cells within single amoeba host cells
Abstract
Here we present the first attempt to quantify Legionella pneumophila cell numbers within individual amoeba hosts that may be released into engineered water systems. The maximum numbers of culturable L. pneumophila cells grown within Acanthamoeba polyphaga and Naegleria fowleri were 1,348 (mean, 329) and 385 (mean, 44) CFU trophozoite(-1), respectively.
Figures
References
-
- Barbaree JM. 1991. Controlling Legionella in cooling towers. ASHRAE J. 33:38–42
-
- Bauer M, et al. 2008. Legionella bacteria in shower aerosols increase the risk of Pontiac fever among older people in retirement homes. J. Epidemiol. Community Health 62:913–920 - PubMed
-
- Berendt RF, Young HW, Allen RG, Knutsen GL. 1980. Dose-response of guinea pigs experimentally infected with aerosols of Legionella pneumophila. J. Infect. Dis. 141:186–192 - PubMed
-
- Breiman RF, et al. 1990. Role of air sampling in investigation of an outbreak of legionnaires' disease associated with exposure to aerosols from an evaporative condenser. J. Infect. Dis. 161:1257–1261 - PubMed