The role of clinical decision support tools to reduce blood pressure variability in critically ill patients receiving vasopressor support
- PMID: 22228216
- DOI: 10.1097/NCN.0b013e3182418c39
The role of clinical decision support tools to reduce blood pressure variability in critically ill patients receiving vasopressor support
Abstract
Current monitoring systems for patients receiving vasopressor support generally rely on bedside monitors with audible alarms that are activated when blood pressure declines below pre-established thresholds, which can result in fluctuations that may increase risk of myocardial ischemia. This pilot study evaluated the effects of three bedside monitors on mean arterial blood pressure and percentage of time at mean arterial pressure among critically ill patients. The monitors were the standard display with audible alarm or one of two types of clinical decision support systems including Intellivue Horizon Trends (Philips Healthcare, Andover, MA) and Horizon Trends and ST Map (Philips Healthcare). Patients in the two groups monitored with Horizon Trends had significantly higher mean arterial pressure (72.8 ± 7.0 mm Hg) compared with those monitored with the standard monitor (68.1 ± 6.8 mm Hg; P= .004). Patients monitored with Horizon Trends also spent a significantly higher percentage of time within their target mean arterial pressure range compared with those in the standard monitor group (P = .031). These findings suggest that further study is needed to assess the impact of clinical decision support tools on management of blood pressure variability in critically ill patients receiving vasopressor therapy.
Similar articles
-
Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.Crit Care. 2006;10(2):R43. doi: 10.1186/cc4852. Crit Care. 2006. PMID: 16542489 Free PMC article.
-
Effect of intravenous propacetamol on blood pressure in febrile critically ill patients.Pharmacotherapy. 2008 Oct;28(10):1205-10. doi: 10.1592/phco.28.10.1205. Pharmacotherapy. 2008. PMID: 18823215
-
Results of a survey of blood pressure monitoring by intensivists in critically ill patients: a preliminary study.Crit Care Med. 2010 Dec;38(12):2335-8. doi: 10.1097/CCM.0b013e3181fa057f. Crit Care Med. 2010. PMID: 20890190
-
Automated Blood Pressure Control.Semin Respir Crit Care Med. 2021 Feb;42(1):47-58. doi: 10.1055/s-0040-1713083. Epub 2020 Aug 3. Semin Respir Crit Care Med. 2021. PMID: 32746471 Review.
-
Pressure ulcer development and vasopressor agents in adult critical care patients: a literature review.Ostomy Wound Manage. 2013 Apr;59(4):50-4, 56-60. Ostomy Wound Manage. 2013. PMID: 23562874 Review.
Cited by
-
Novel displays of patient information in critical care settings: a systematic review.J Am Med Inform Assoc. 2019 May 1;26(5):479-489. doi: 10.1093/jamia/ocy193. J Am Med Inform Assoc. 2019. PMID: 30865769 Free PMC article.
-
Overview of Wearable Healthcare Devices for Clinical Decision Support in the Prehospital Setting.Sensors (Basel). 2024 Dec 22;24(24):8204. doi: 10.3390/s24248204. Sensors (Basel). 2024. PMID: 39771939 Free PMC article. Review.
-
Computerized decision support in adult and pediatric critical care.World J Crit Care Med. 2013 Nov 4;2(4):21-8. doi: 10.5492/wjccm.v2.i4.21. eCollection 2013 Nov 4. World J Crit Care Med. 2013. PMID: 24701413 Free PMC article. Review.
-
Situation Awareness-Oriented Patient Monitoring with Visual Patient Technology: A Qualitative Review of the Primary Research.Sensors (Basel). 2020 Apr 9;20(7):2112. doi: 10.3390/s20072112. Sensors (Basel). 2020. PMID: 32283625 Free PMC article. Review.
-
Critical care information display approaches and design frameworks: A systematic review and meta-analysis.J Biomed Inform X. 2019 Sep;3:100041. doi: 10.1016/j.yjbinx.2019.100041. Epub 2019 Jun 22. J Biomed Inform X. 2019. PMID: 31423485 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical