Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
- PMID: 22228411
- DOI: 10.1007/s10840-011-9646-1
Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
Abstract
Background: Due to the variable anatomy of the human pulmonary vein (PV), PV isolation for atrial fibrillation ablation is challenging. A novel hot balloon ablation catheter has been developed to improve ablation outcomes. The efficacy, histopathologic lesion characteristics, and thermodynamics of this technology were examined.
Methods: Swine underwent left atrial (n = 24) and superior vena cava (SVC, n = 7) catheterization with a compliant balloon catheter filled with saline and contrast. After PV mapping and angiography, ablation was performed with radiofrequency energy heating of the balloon contents. Central balloon temperatures were varied from 60°C to 90°C, and durations of energy delivery were varied from 60 to 300 s. Endocardial and epicardial temperatures were recorded contiguous to the balloon during SVC ablations. Pathology was examined.
Results: With a mean of 1.4 ± 0.9 ablations per PV at 70°C, 93% were electrically isolated. Necropsy exam revealed extraostial lesions without charring. PVs ablated at temperatures ≥80°C and durations ≥180 s were associated with a high rate of successful isolation with a single ablation. Higher-temperature lesions displayed greater histopathologic uniformity, but more marked fibrin deposition. Chronic lesions revealed granulation tissue and fibrosis. No thromboembolic events were observed and histopathology of the phrenic nerve and esophagus was normal in all specimens.
Conclusions: The hot balloon ablation catheter appears to be a safe and effective tool for PV isolation. Higher temperatures and longer ablation durations are associated with a higher single ablation success rate.
Similar articles
-
The durability of pulmonary vein isolation using the visually guided laser balloon catheter: multicenter results of pulmonary vein remapping studies.Heart Rhythm. 2012 Jun;9(6):919-25. doi: 10.1016/j.hrthm.2012.01.019. Epub 2012 Jan 28. Heart Rhythm. 2012. PMID: 22293143 Clinical Trial.
-
A porcine study of the area of heated tissue during hot-balloon ablation: Implications for the clinical efficacy and safety.J Cardiovasc Electrophysiol. 2021 Feb;32(2):260-269. doi: 10.1111/jce.14861. Epub 2021 Jan 11. J Cardiovasc Electrophysiol. 2021. PMID: 33382509
-
Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery: Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE).Circ Arrhythm Electrophysiol. 2019 Dec;12(12):e007541. doi: 10.1161/CIRCEP.119.007541. Epub 2019 Dec 12. Circ Arrhythm Electrophysiol. 2019. PMID: 31826648 Clinical Trial.
-
Balloon catheters for pulmonary vein isolation.Herz. 2008 Dec;33(8):580-4. doi: 10.1007/s00059-008-3176-3. Herz. 2008. PMID: 19137248 Review.
-
Novel Ablation Approaches for Challenging Atrial Fibrillation Cases (Mapping, Irrigation, and Catheters).Cardiol Clin. 2019 May;37(2):207-219. doi: 10.1016/j.ccl.2019.01.012. Cardiol Clin. 2019. PMID: 30926022 Review.
Cited by
-
2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.Heart Rhythm. 2012 Apr;9(4):632-696.e21. doi: 10.1016/j.hrthm.2011.12.016. Epub 2012 Mar 1. Heart Rhythm. 2012. PMID: 22386883 No abstract available.
-
Balloon surface temperature-controlled ablation using a second-generation radiofrequency HotBalloon: an in vivo feasibility study.Europace. 2023 Dec 6;25(12):euad340. doi: 10.1093/europace/euad340. Europace. 2023. PMID: 37950630 Free PMC article.
-
Current hot potatoes in atrial fibrillation ablation.Curr Cardiol Rev. 2012 Nov;8(4):327-46. doi: 10.2174/157340312803760802. Curr Cardiol Rev. 2012. PMID: 22920482 Free PMC article. Review.
-
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary.J Arrhythm. 2017 Oct;33(5):369-409. doi: 10.1016/j.joa.2017.08.001. Epub 2017 Sep 15. J Arrhythm. 2017. PMID: 29021841 Free PMC article. No abstract available.
-
Lesion durability after antral pulmonary vein isolation using a radiofrequency hot balloon catheter.J Interv Card Electrophysiol. 2021 Oct;62(1):21-30. doi: 10.1007/s10840-020-00857-0. Epub 2020 Sep 16. J Interv Card Electrophysiol. 2021. PMID: 32939701
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials