Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jun;34(1):29-36.
doi: 10.1007/s10840-011-9646-1. Epub 2012 Jan 8.

Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter

Affiliations

Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter

Rudolph F Evonich et al. J Interv Card Electrophysiol. 2012 Jun.

Abstract

Background: Due to the variable anatomy of the human pulmonary vein (PV), PV isolation for atrial fibrillation ablation is challenging. A novel hot balloon ablation catheter has been developed to improve ablation outcomes. The efficacy, histopathologic lesion characteristics, and thermodynamics of this technology were examined.

Methods: Swine underwent left atrial (n = 24) and superior vena cava (SVC, n = 7) catheterization with a compliant balloon catheter filled with saline and contrast. After PV mapping and angiography, ablation was performed with radiofrequency energy heating of the balloon contents. Central balloon temperatures were varied from 60°C to 90°C, and durations of energy delivery were varied from 60 to 300 s. Endocardial and epicardial temperatures were recorded contiguous to the balloon during SVC ablations. Pathology was examined.

Results: With a mean of 1.4 ± 0.9 ablations per PV at 70°C, 93% were electrically isolated. Necropsy exam revealed extraostial lesions without charring. PVs ablated at temperatures ≥80°C and durations ≥180 s were associated with a high rate of successful isolation with a single ablation. Higher-temperature lesions displayed greater histopathologic uniformity, but more marked fibrin deposition. Chronic lesions revealed granulation tissue and fibrosis. No thromboembolic events were observed and histopathology of the phrenic nerve and esophagus was normal in all specimens.

Conclusions: The hot balloon ablation catheter appears to be a safe and effective tool for PV isolation. Higher temperatures and longer ablation durations are associated with a higher single ablation success rate.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Cardiovasc Electrophysiol. 2003 Jun;14(6):609-15 - PubMed
    1. Heart Rhythm. 2007 Jun;4(6):816-61 - PubMed
    1. N Engl J Med. 2006 Mar 2;354(9):934-41 - PubMed
    1. Circulation. 2000 Mar 28;101(12):1409-17 - PubMed
    1. J Am Coll Cardiol. 2003 Jul 16;42(2):185-97 - PubMed

Publication types

LinkOut - more resources