Exact sample-size determination in testing non-inferiority under a simple crossover trial
- PMID: 22232060
- DOI: 10.1002/pst.506
Exact sample-size determination in testing non-inferiority under a simple crossover trial
Abstract
For testing the non-inferiority (or equivalence) of an experimental treatment to a standard treatment, the odds ratio (OR) of patient response rates has been recommended to measure the relative treatment efficacy. On the basis of an exact test procedure proposed elsewhere for a simple crossover design, we develop an exact sample-size calculation procedure with respect to the OR of patient response rates for a desired power of detecting non-inferiority at a given nominal type I error. We note that the sample size calculated for a desired power based on an asymptotic test procedure can be much smaller than that based on the exact test procedure under a given situation. We further discuss the advantage and disadvantage of sample-size calculation using the exact test and the asymptotic test procedures. We employ an example by studying two inhalation devices for asthmatics to illustrate the use of sample-size calculation procedure developed here.
Copyright © 2012 John Wiley & Sons, Ltd.