Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2012 Mar;35(5):529-39.
doi: 10.1111/j.1365-2036.2011.04975.x. Epub 2012 Jan 13.

Meta-analysis: diagnostic medical radiation exposure in inflammatory bowel disease

Affiliations
Meta-Analysis

Meta-analysis: diagnostic medical radiation exposure in inflammatory bowel disease

S Chatu et al. Aliment Pharmacol Ther. 2012 Mar.

Abstract

Background: Diagnostic imaging plays a pivotal role in the diagnosis and management of inflammatory bowel disease (IBD); however, increasing use has led to concerns about the malignant potential of ionising radiation. Several studies have demonstrated that diagnostic imaging can result in exposure to potentially harmful levels of ionising radiation in IBD patients.

Aim: To determine the pooled prevalence of increased exposure and pooled odds ratio of risk factors associated with exposure to potentially harmful levels of diagnostic medical radiation.

Methods: We searched Medline, EMBASE, CINHAL and reference lists of identified articles, without language restrictions in October 2011.

Results: Six studies with 1704 participants provided data on the proportion of patients receiving potentially harmful levels of radiation defined as ≥50 milli-sieverts (mSv)-equivalent to 5 CT abdomen scans. The pooled prevalence was 8.8% (95% CI 4.4-16.8) for IBD patients and 11.1% (95% CI 5.7-20.5%) and 2% (95% CI 0.8-4.9%) for Crohn's disease and ulcerative colitis patients respectively. Five studies involving 2627 participants provided data for risk factors. IBD-related surgery and corticosteroid use were significant with pooled adjusted odds ratio of 5.4 (95% CI 2.6-11.2) and 2.4 (95% CI 1.7-3.4) respectively.

Conclusions: About 1 in 10 patients may be exposed to potentially harmful levels of diagnostic medical radiation. Corticosteroid use and IBD related surgery increased this risk. Strategies to reduce radiation exposure while assessing disease activity need to be considered.

PubMed Disclaimer

Publication types

LinkOut - more resources