Assessment of linear regression techniques for modeling multisensor data for non-invasive continuous glucose monitoring
- PMID: 22254858
- DOI: 10.1109/IEMBS.2011.6090702
Assessment of linear regression techniques for modeling multisensor data for non-invasive continuous glucose monitoring
Abstract
New scenarios in diabetes treatment have been opened in the last ten years by continuous glucose monitoring (CGM) sensors. In particular, Non-Invasive CGM sensors are particularly appealing, even though they are still at an early stage of development. Solianis Monitoring AG (Zürich, Switzerland) has proposed an approach based on a multisensor concept, embedding primarily dielectric spectroscopy and optical sensors. This concept requires a mathematical model able to reconstruct the glucose concentration from the 150 channels measured with the device. Assuming a multivariate linear regression model (valid and usable for different individuals), the aim of this paper is the assessment of some techniques usable for determining such a model, namely Ordinary Least Squares (OLS), Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO). Once the model is identified on a training set, the accuracy of prospective glucose profiles estimated from "unseen" multisensor data is assessed. Preliminary results obtained from 18 in-clinic study days show that sufficiently accurate reconstruction of glucose levels can be achieved if suitable model identification techniques, such as LASSO, are considered.
Similar articles
-
Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system.Med Biol Eng Comput. 2012 Oct;50(10):1047-57. doi: 10.1007/s11517-012-0932-6. Epub 2012 Jun 22. Med Biol Eng Comput. 2012. PMID: 22722898
-
Non-invasive glucose monitoring in patients with Type 1 diabetes: a Multisensor system combining sensors for dielectric and optical characterisation of skin.Biosens Bioelectron. 2009 May 15;24(9):2778-84. doi: 10.1016/j.bios.2009.02.001. Epub 2009 Feb 20. Biosens Bioelectron. 2009. PMID: 19286364
-
Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device.Sensors (Basel). 2019 Aug 24;19(17):3677. doi: 10.3390/s19173677. Sensors (Basel). 2019. PMID: 31450547 Free PMC article.
-
Sensor-augmented pump therapy in type 1 diabetes.Curr Opin Endocrinol Diabetes Obes. 2008 Apr;15(2):118-22. doi: 10.1097/MED.0b013e3282f7960b. Curr Opin Endocrinol Diabetes Obes. 2008. PMID: 18316945 Review.
-
Consensus Statement on Inpatient Use of Continuous Glucose Monitoring.J Diabetes Sci Technol. 2017 Sep;11(5):1036-1044. doi: 10.1177/1932296817706151. Epub 2017 Apr 21. J Diabetes Sci Technol. 2017. PMID: 28429611 Free PMC article.
Cited by
-
Non-Invasive Blood Glucose Monitoring Technology: A Review.Sensors (Basel). 2020 Dec 4;20(23):6925. doi: 10.3390/s20236925. Sensors (Basel). 2020. PMID: 33291519 Free PMC article. Review.
-
Differentiation of cancer cells in two-dimensional and three-dimensional breast cancer models by Raman spectroscopy.J Biomed Opt. 2013 Nov;18(11):117008. doi: 10.1117/1.JBO.18.11.117008. J Biomed Opt. 2013. PMID: 24247810 Free PMC article.
-
Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy.Sci Adv. 2020 Jun 10;6(24):eaba5320. doi: 10.1126/sciadv.aba5320. eCollection 2020 Jun. Sci Adv. 2020. PMID: 32577523 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical