Simultaneous comparison of 24-hour intragastric pH recording using glass and antimony electrodes in man
- PMID: 2225518
- DOI: 10.1159/000171278
Simultaneous comparison of 24-hour intragastric pH recording using glass and antimony electrodes in man
Abstract
Based upon the results of in vitro studies, antimony electrodes are generally considered to have inferior electrochemical properties when compared with glass electrodes. Since a direct comparison in man is lacking, a 24-hour ambulatory intragastric pH recording was performed in 10 healthy male subjects simultaneously using glass and antimony electrodes. In the first set of experiments (when both electrodes were calibrated in buffers of pH 7 and 1 at 37 degrees C: beaker calibration) significantly lower pH recordings during fasting periods were registered with the antimony electrode. This difference could be corrected by a modified calibration, using the external skin reference electrode of the antimony electrode (finger calibration). In the second series of experiments (performed after finger calibration) comparable recordings of 24-hour intragastric pH could be obtained with antimony and glass electrodes in the same subjects. The reason for statistically insignificant differences of pH recordings with both electrodes in the early hours of the morning remains uncertain. The drift of glass and antimony electrodes did not differ. It is concluded from these data that, after adequate calibration, inferior electrochemical properties of antimony electrodes do not influence intragastric pH recordings in man.
Similar articles
-
Glass and antimony electrodes for long-term pH monitoring: a dynamic in vitro comparison.Eur J Gastroenterol Hepatol. 1995 Jan;7(1):29-35. Eur J Gastroenterol Hepatol. 1995. PMID: 7866807
-
Electrochemical aspects of pH electrodes.Dig Dis. 1990;8 Suppl 1:18-22. doi: 10.1159/000171275. Dig Dis. 1990. PMID: 2225514
-
Ambulatory oesophageal pH monitoring: a comparison between antimony, ISFET, and glass pH electrodes.Eur J Gastroenterol Hepatol. 2010 May;22(5):572-7. doi: 10.1097/MEG.0b013e328333139f. Eur J Gastroenterol Hepatol. 2010. PMID: 20009939 Clinical Trial.
-
24-h recording of intragastric pH: technical aspects and clinical relevance.Scand J Gastroenterol Suppl. 1999;230:9-16. Scand J Gastroenterol Suppl. 1999. PMID: 10499456 Review.
-
[Acid-related pathology and prolonged continuous gastric pH monitoring. Physiopathologic findings and therapeutic implications].Recenti Prog Med. 1989 Sep;80(9):485-92. Recenti Prog Med. 1989. PMID: 2574489 Review. Italian.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources