Hemodynamic performance of NMES in the early post operative period following orthopaedic surgery
- PMID: 22256105
- DOI: 10.1109/IEMBS.2011.6091880
Hemodynamic performance of NMES in the early post operative period following orthopaedic surgery
Abstract
Patients post total hip arthroplasty (THA) remain at high risk of developing Deep Vein Thrombosis (DVT) during the recovery period following surgery. The use of calf muscle neuromuscular electrical stimulation (NMES) during the hospitalized recovery period on this patient group may be effective at preventing DVT. However, the haemodynamic effectiveness and comfort characteristics of NMES in post-THA patients immediately following surgery has yet to be demonstrated. The popliteal veins of 5 patients, who had undergone unilateral total hip replacement surgery on the day previous to the study, were measured using Doppler ultrasound during a 4 hour calf-muscle NMES session. The effect of calf muscle NMES on peak venous velocity and volume flow were compared to resting values. Comfort was assessed using a 100 mm non-hatched visual analogue scale taken before application of NMES, once NMES was initiated and before NMES was withdrawn. Results of the study showed that NMES produces a beneficial hemodynamic response in patients in the early postoperative period following orthopaedic surgery. This patient group found extended periods of calf-muscle NMES tolerable.
Similar articles
-
Haemodynamic performance of neuromuscular electrical stimulation (NMES) during recovery from total hip arthroplasty.J Orthop Surg Res. 2013 Mar 5;8:3. doi: 10.1186/1749-799X-8-3. J Orthop Surg Res. 2013. PMID: 23497524 Free PMC article. Clinical Trial.
-
Patient tolerance of neuromuscular electrical stimulation (NMES) in the presence of orthopaedic implants.Med Eng Phys. 2011 Jan;33(1):56-61. doi: 10.1016/j.medengphy.2010.09.003. Med Eng Phys. 2011. PMID: 20926329 Clinical Trial.
-
The influence of orthopaedic implants on patient tolerance of neuromuscular electrical stimulation (NMES).Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:5823-6. doi: 10.1109/IEMBS.2010.5627491. Annu Int Conf IEEE Eng Med Biol Soc. 2010. PMID: 21096915 Clinical Trial.
-
A Review of the Evidence to Support Neuromuscular Electrical Stimulation in the Prevention and Management of Venous Disease.Adv Exp Med Biol. 2017;906:377-386. doi: 10.1007/5584_2016_128. Adv Exp Med Biol. 2017. PMID: 27620314 Review.
-
Neuromuscular electrical stimulation is effective in strengthening the quadriceps muscle after anterior cruciate ligament surgery.Knee Surg Sports Traumatol Arthrosc. 2018 Feb;26(2):399-410. doi: 10.1007/s00167-017-4669-5. Epub 2017 Aug 17. Knee Surg Sports Traumatol Arthrosc. 2018. PMID: 28819679 Review.
Cited by
-
Effect of neuromuscular electrical stimulation on the recovery of people with COVID-19 admitted to the intensive care unit: A narrative review.J Rehabil Med. 2021 Mar 18;53(3):jrm00164. doi: 10.2340/16501977-2805. J Rehabil Med. 2021. PMID: 33634830 Free PMC article. Review.
-
The geko™ electro-stimulation device for venous thromboembolism prophylaxis: a NICE medical technology guidance.Appl Health Econ Health Policy. 2015 Apr;13(2):135-47. doi: 10.1007/s40258-014-0139-0. Appl Health Econ Health Policy. 2015. PMID: 25403719 Free PMC article.