Jugular bulb catheterization: experience with 123 patients
- PMID: 2225889
- DOI: 10.1097/00003246-199011000-00006
Jugular bulb catheterization: experience with 123 patients
Abstract
Jugular bulb catheterization (JBC) provides cerebral venous access for titration of brain-specific therapy. Little has been written about the catheterization procedure. We prospectively studied the time, number of punctures, success rate, and complications during JBC for a 24-month period in our ICUs. One hundred twenty-three patients (mean age 6.7 yr, range 12 hours to 21 yr) underwent JBC. Procedure time was 15.6 +/- 5.0 (SD) min. Median number of skin punctures was two. All but four were successful on first attempt. Three of the remaining were catheterized on second attempt. Inadvertent carotid puncture occurred in 3%. No other significant complications were noted. Radiography confirmed proper position in 97%. Duration of indwelling venous catheters was 2.5 +/- 1.6 days. All catheters functioned well until removal. We conclude that our technique of JBC is safe and highly successful. It compares favorably with previous, smaller series and with standard anterograde internal jugular catheterization in both children and adults.
Similar articles
-
Jugular bulb catheterization does not increase intracranial pressure.Intensive Care Med. 1991;17(4):195-8. doi: 10.1007/BF01709876. Intensive Care Med. 1991. PMID: 1744302
-
Jugular venous bulb catheterization in infants and children.Crit Care Med. 1989 May;17(5):385-8. doi: 10.1097/00003246-198905000-00001. Crit Care Med. 1989. PMID: 2707008
-
Are femoral Broviac catheters effective and safe? A prospective comparison of femoral and jugular venous broviac catheters in newborn infants.Chest. 2002 May;121(5):1527-30. doi: 10.1378/chest.121.5.1527. Chest. 2002. PMID: 12006439
-
Ultrasound-guided vascular access in adults and children: beyond the internal jugular vein puncture.Acta Anaesthesiol Belg. 2008;59(3):157-66. Acta Anaesthesiol Belg. 2008. PMID: 19051447 Review.
-
Peripheral and central venous access.Semin Pediatr Surg. 1992 Aug;1(3):181-7. Semin Pediatr Surg. 1992. PMID: 1345486 Review.
Cited by
-
Jugular bulb catheterization does not increase intracranial pressure.Intensive Care Med. 1991;17(4):195-8. doi: 10.1007/BF01709876. Intensive Care Med. 1991. PMID: 1744302
-
Differences in oxygen content between mixed venous blood and cerebral venous blood for outcome prediction after cardiac arrest.Intensive Care Med. 1995 Jan;21(1):71-5. doi: 10.1007/BF02425158. Intensive Care Med. 1995. PMID: 7560479
-
Neuromonitoring in defibrillation threshold testing. A comparison between EEG, near-infrared spectroscopy and jugular bulb oximetry.J Clin Monit. 1997 Sep;13(5):303-7. doi: 10.1023/a:1007323823806. J Clin Monit. 1997. PMID: 9338844
-
The effect of molecular adsorbent recirculating system on pathophysiological parameters in patients with acute liver failure.Intensive Care Med. 2005 Nov;31(11):1544-9. doi: 10.1007/s00134-005-2786-y. Epub 2005 Sep 10. Intensive Care Med. 2005. PMID: 16155752 Clinical Trial.
-
Arterio-jugular differences of oxygen (AVDO2) for bedside assessment of CO2-reactivity and autoregulation in the acute phase of severe head injury.Acta Neurochir (Wien). 1996;138(4):435-44. doi: 10.1007/BF01420306. Acta Neurochir (Wien). 1996. PMID: 8738394
MeSH terms
LinkOut - more resources
Full Text Sources