Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study
- PMID: 22264204
- DOI: 10.1111/j.1365-2591.2012.02014.x
Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study
Abstract
Aim: To compare the efficacy of two rotary NiTi retreatment systems and Hedström files in removing filling material from curved root canals.
Methodology: Curved root canals of 57 extracted teeth were prepared using FlexMaster instruments and filled with gutta-percha and AH Plus. After determination of root canal curvatures and radii in two directions, the teeth were assigned to three identical groups (n = 19). The root fillings were removed with D-RaCe instruments, ProTaper Universal Retreatment instruments or Hedström files. Pre- and postoperative micro-CT imaging was used to assess the percentage of residual filling material as well as the amount of dentine removal. Working time and procedural errors were recorded. Data were analysed using analysis of covariance and analysis of variance procedures.
Results: D-RaCe instruments were significantly more effective than ProTaper Universal Retreatment instruments and Hedström files (P < 0.05). Hedström files removed significantly less dentine than the rotary NiTi systems (P < 0.0001). D-RaCe instruments were significantly faster compared to both other groups (P < 0.05). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected in the Hedström group. In the ProTaper group, four instrument fractures and one lateral perforation were observed. Five instrument fractures were recorded for D-RaCe.
Conclusions: D-RaCe instruments were associated with significantly less residual filling material than ProTaper Universal Retreatment instruments and hand files. Hedström files removed significantly less dentine than both rotary NiTi systems. Retreatment with rotary NiTi systems resulted in a high incidence of procedural errors.
© 2012 International Endodontic Journal.
Similar articles
-
Efficacy of three different rotary files to remove gutta-percha and Resilon from root canals.Int Endod J. 2010 Nov;43(11):1022-8. doi: 10.1111/j.1365-2591.2010.01758.x. Epub 2010 Aug 19. Int Endod J. 2010. PMID: 20726911 Clinical Trial.
-
Comparison of hand and rotary instrumentation for removing gutta-percha from previously treated curved root canals: a microcomputed tomography study.Int Endod J. 2014 Feb;47(2):173-82. doi: 10.1111/iej.12128. Epub 2013 May 24. Int Endod J. 2014. PMID: 23701239
-
Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT.Int Endod J. 2014 Oct;47(10):942-8. doi: 10.1111/iej.12239. Epub 2014 Feb 1. Int Endod J. 2014. PMID: 24386931
-
Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments.J Endod. 2013 Feb;39(2):163-72. doi: 10.1016/j.joen.2012.11.005. J Endod. 2013. PMID: 23321225 Review.
-
Impact of nickel-titanium instrumentation of the root canal on clinical outcomes: a focused review.Odontology. 2012 Jul;100(2):130-6. doi: 10.1007/s10266-012-0066-1. Epub 2012 Apr 22. Odontology. 2012. PMID: 22527909 Review.
Cited by
-
Endodontic retreatment efficacy with and without solvents: A systematic review.J Conserv Dent Endod. 2023 Nov-Dec;26(6):610-615. doi: 10.4103/JCDE.JCDE_86_23. Epub 2023 Nov 22. J Conserv Dent Endod. 2023. PMID: 38292751 Free PMC article. Review.
-
Effect of different retreatment files using different kinematics on the release of inflammatory mediators in root canal retreatment of single-rooted teeth: a randomized clinical trial.Clin Oral Investig. 2023 Jun;27(6):3189-3196. doi: 10.1007/s00784-023-04930-6. Epub 2023 Mar 1. Clin Oral Investig. 2023. PMID: 36856848 Clinical Trial.
-
Comparative evaluation of marginal adaptation of mineral trioxide aggregate, Biodentine, and geristore as a root end filling material: An in vitro scanning electron microscope study.J Conserv Dent Endod. 2023 Jul-Aug;26(4):447-452. doi: 10.4103/jcd.jcd_55_21. Epub 2023 Jul 28. J Conserv Dent Endod. 2023. PMID: 37705552 Free PMC article.
-
Cleanliness of Canal Walls following Gutta-Percha Removal with Hand Files, RaCe and RaCe plus XP-Endo Finisher Instruments: A Photographic in Vitro Analysis.Iran Endod J. 2017 Spring;12(2):242-247. doi: 10.22037/iej.2017.47. Iran Endod J. 2017. PMID: 28512494 Free PMC article.
-
In vitro comparative evaluation of efficiency of XP-endo shaper, XP-endo finisher, and XP-endo finisher-R files in terms of residual root filling material, preservation of root dentin, and time during retreatment procedures in oval canals - A cone-beam computed tomography analysis.J Conserv Dent. 2020 Mar-Apr;23(2):145-151. doi: 10.4103/JCD.JCD_257_20. Epub 2020 Nov 5. J Conserv Dent. 2020. PMID: 33384486 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources