Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Oct;81(10):2543-9.
doi: 10.1016/j.ejrad.2011.12.026. Epub 2012 Jan 20.

Semi-automatic software increases CT measurement accuracy but not response classification of colorectal liver metastases after chemotherapy

Affiliations

Semi-automatic software increases CT measurement accuracy but not response classification of colorectal liver metastases after chemotherapy

Charlotte S van Kessel et al. Eur J Radiol. 2012 Oct.

Abstract

Objectives: This study evaluates intra- and interobserver variability of automatic diameter and volume measurements of colorectal liver metastases (CRLM) before and after chemotherapy and its influence on response classification.

Methods: Pre-and post-chemotherapy CT-scans of 33 patients with 138 CRLM were evaluated. Two observers measured all metastases three times on pre-and post-chemotherapy CT-scans, using three different techniques: manual diameter (MD), automatic diameter (AD) and automatic volume (AV). RECIST 1.0 criteria were used to define response classification. For each technique, we assessed intra- and interobserver reliability by determining the intraclass correlation coefficient (α-level 0.05). Intra-observer agreement was estimated by the variance coefficient (%). For inter-observer agreement the relative measurement error (%) was calculated using Bland-Altman analysis. In addition, we compared agreement in response classification by calculating kappa-scores (κ) and estimating proportions of discordance between methods (%).

Results: Intra-observer variability was 6.05%, 4.28% and 12.72% for MD, AD and AV, respectively. Inter-observer variability was 4.23%, 2.02% and 14.86% for MD, AD and AV, respectively. Chemotherapy marginally affected these estimates. Agreement in response classification did not improve using AD or AV (MD κ=0.653, AD κ=0.548, AV κ=0.548) and substantial discordance between observers was observed with all three methods (MD 17.8%, AD 22.2%, AV 22.2%).

Conclusion: Semi-automatic software allows repeatable and reproducible measurement of both diameter and volume measurements of CRLM, but does not reduce variability in response classification.

PubMed Disclaimer

MeSH terms

Substances