. 2012 Mar;102(3):377-82.
doi: 10.1016/j.radonc.2011.12.015. Epub 2012 Jan 20.

Evaluating FDG uptake changes between pre and post therapy respiratory gated PET scans

Affiliations

Evaluating FDG uptake changes between pre and post therapy respiratory gated PET scans

Michalis Aristophanous et al. Radiother Oncol. 2012 Mar.

Abstract

Purpose: Whole body (3D) and respiratory gated (4D) FDG-PET/CT scans performed pre-radiotherapy (pre-RT) and post-radiotherapy (post-RT) were analyzed to investigate the impact of 4D PET in evaluating 18F-fluorodeoxyglucose (FDG) uptake changes due to therapy, relative to traditional 3D PET.

Methods and materials: 3D and 4D sequential FDG-PET/CT scans were acquired pre-RT and approximately one month post-RT for patients with non-small cell lung cancer (NSCLC). The lesions of high uptake targeted with radiotherapy were identified on the pre-RT scan of each patient. Each lesion on the 3D and each of the five phases of the 4D scan were analyzed using a region of interest (ROI). For each patient the ROIs of the pre-RT scans were used to locate the areas of initial FDG uptake on the post-RT scans following rigid registration. Post-RT ROIs were drawn and the FDG uptake was compared with that of the pre-RT scans.

Results: Sixteen distinct lesions from 12 patients were identified and analyzed. Standardized uptake value (SUV) maxima were significantly higher (p-value <0.005) for the lesions as measured on the 4D compared to 3D PET. Comparison of serial pre and post-RT scans showed a mean 62% decrease in SUV with the 3D PET scan (range 36-89%), and a 67% decrease with the 4D PET scan (range 30-89%). The mean absolute difference in SUV change on 3D versus 4D scans was 4.9%, with a range 0-15% (p-value = 0.07).

Conclusions: Signal recovery with 4D PET results in higher SUVs when compared to standard 3D PET. Consequently, differences in the evaluation of SUV changes between pre and post-RT plans were observed. Such difference can have a significant impact in PET-based response assessment.

PubMed Disclaimer

Substances