Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Sep;22(7):559-64.
doi: 10.1097/IJG.0b013e31824484b9.

Comparison of sensitivities for detecting diffuse and localized retinal nerve fiber layer defects with time-domain optical coherence tomography in patients with glaucoma

Affiliations
Comparative Study

Comparison of sensitivities for detecting diffuse and localized retinal nerve fiber layer defects with time-domain optical coherence tomography in patients with glaucoma

Young Cheol Yoo et al. J Glaucoma. 2013 Sep.

Abstract

Purpose: To compare the ability of time-domain optical coherence tomography (OCT) to detect diffuse and localized retinal nerve fiber layer (RNFL) defects using a built-in normative database in patients with early to moderate glaucoma.

Methods: Subjects with localized visual field defects confined to either hemifield were consecutively recruited. Only 1 eye per subject was considered. Among the 91 eyes with localized RNFL defects, 46 eyes with mean deviations matched to those of the 46 eyes with diffuse RNFL defects were selected for statistical analysis. This case-control study included 46 eyes with diffuse RNFL defects and 46 eyes with localized RNFL defects. The fast RNFL thickness protocol of Stratus OCT was used. The clock-hour and quadrant sector parameters corresponding to the hemifield with the visual field defect were evaluated at P<0.05 with regard to the built-in normative database. The sensitivities of these parameters were compared between diffuse and localized RNFL defects.

Results: The sensitivity of the clock-hour sector parameter for diffuse RNFL defects (84.8%) was not significantly different than that for localized RNFL defects (80.4%) (P=0.78). The sensitivity of the quadrant sector parameter for diffuse RNFL defects (74.9%) was significantly higher than that for localized RNFL defects (52.3%) (P=0.04).

Conclusions: The clock-hour parameter of time-domain OCT detected RNFL defects without significant difference in sensitivities between diffuse and localized patterns of RNFL loss in glaucomatous eyes. However, the quadrant parameter of OCT showed better sensitivity for diffuse RNFL defects than for localized RNFL defects.

PubMed Disclaimer

Publication types

LinkOut - more resources