Dry-contact and noncontact biopotential electrodes: methodological review
- PMID: 22275204
- DOI: 10.1109/RBME.2010.2084078
Dry-contact and noncontact biopotential electrodes: methodological review
Abstract
Recent demand and interest in wireless, mobile-based healthcare has driven significant interest towards developing alternative biopotential electrodes for patient physiological monitoring. The conventional wet adhesive Ag/AgCl electrodes used almost universally in clinical applications today provide an excellent signal but are cumbersome and irritating for mobile use. While electrodes that operate without gels, adhesives and even skin contact have been known for many decades, they have yet to achieve any acceptance for medical use. In addition, detailed knowledge and comparisons between different electrodes are not well known in the literature. In this paper, we explore the use of dry/noncontact electrodes for clinical use by first explaining the electrical models for dry, insulated and noncontact electrodes and show the performance limits, along with measured data. The theory and data show that the common practice of minimizing electrode resistance may not always be necessary and actually lead to increased noise depending on coupling capacitance. Theoretical analysis is followed by an extensive review of the latest dry electrode developments in the literature. The paper concludes with highlighting some of the novel systems that dry electrode technology has enabled for cardiac and neural monitoring followed by a discussion of the current challenges and a roadmap going forward.
Similar articles
-
Nanofiber web textile dry electrodes for long-term biopotential recording.IEEE Trans Biomed Circuits Syst. 2013 Apr;7(2):204-11. doi: 10.1109/TBCAS.2012.2201154. IEEE Trans Biomed Circuits Syst. 2013. PMID: 23853303
-
Biopotential fiber sensor.J Electrocardiol. 2006 Oct;39(4 Suppl):S41-6. doi: 10.1016/j.jelectrocard.2006.05.016. J Electrocardiol. 2006. PMID: 17015067
-
Dry and noncontact EEG sensors for mobile brain-computer interfaces.IEEE Trans Neural Syst Rehabil Eng. 2012 Mar;20(2):228-35. doi: 10.1109/TNSRE.2011.2174652. Epub 2011 Dec 12. IEEE Trans Neural Syst Rehabil Eng. 2012. PMID: 22180514
-
Dry electrodes for electrocardiography.Physiol Meas. 2013 Sep;34(9):R47-69. doi: 10.1088/0967-3334/34/9/r47. Physiol Meas. 2013. PMID: 24137716 Review.
-
Insulating electrodes: a review on biopotential front ends for dielectric skin-electrode interfaces.Physiol Meas. 2010 Oct;31(10):S183-98. doi: 10.1088/0967-3334/31/10/S03. Epub 2010 Sep 10. Physiol Meas. 2010. PMID: 20834109 Review.
Cited by
-
Wearable Devices for Remote Monitoring of Heart Rate and Heart Rate Variability-What We Know and What Is Coming.Sensors (Basel). 2022 Nov 17;22(22):8903. doi: 10.3390/s22228903. Sensors (Basel). 2022. PMID: 36433498 Free PMC article. Review.
-
Biosensors for immune cell analysis-A perspective.Biomicrofluidics. 2012 Jun;6(2):21301-2130113. doi: 10.1063/1.4706845. Epub 2012 Apr 26. Biomicrofluidics. 2012. PMID: 22655003 Free PMC article.
-
Wearable electrochemical biosensors to measure biomarkers with complex blood-to-sweat partition such as proteins and hormones.Mikrochim Acta. 2022 Mar 1;189(3):127. doi: 10.1007/s00604-022-05228-2. Mikrochim Acta. 2022. PMID: 35233646 Free PMC article. Review.
-
Exploring textile-based electrode materials for electromyography smart garments.J Rehabil Assist Technol Eng. 2022 Feb 1;9:20556683211061995. doi: 10.1177/20556683211061995. eCollection 2022 Jan-Dec. J Rehabil Assist Technol Eng. 2022. PMID: 35127129 Free PMC article.
-
Additively Manufactured Pneumatically Driven Skin Electrodes.Materials (Basel). 2017 Dec 23;11(1):19. doi: 10.3390/ma11010019. Materials (Basel). 2017. PMID: 29295508 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources