Platelet reduction after stentless pericardial aortic valve replacement
- PMID: 22279119
- PMCID: PMC3309805
- DOI: 10.1093/icvts/ivr069
Platelet reduction after stentless pericardial aortic valve replacement
Abstract
The aim of the study was to investigate the multi-factorial phenomenon of possible postoperative thrombocytopenia after aortic valve replacement (AVR) with the freedom SOLO (FS) bioprosthesis. A total of 254 patients underwent AVR with FS bioprosthesis in two cardiac surgery institutes. Platelet counts were measured preoperatively, immediately postoperatively and daily until the 11th day postoperatively. A multivariate generalized estimating equation model was applied to identify prognostic factors for whether or not patients postoperative platelet counts indicated no thrombocytopenia (platelet count >150 10(3)/mm(3)) versus at least mild thrombocytopenia (≤150 10(3)/mm(3)). Preoperatively, 11.2% of patients showed thrombocytopenia. The preoperative platelet count averaged 233.0 ± 83.2 10(3)/mm(3). The postoperative mean of platelet counts decreased daily reaching a minimum mean of 88.4 ± 58.8 10(3)/mm(3) 3 days after surgery and then started to increase, with the Day 11 postoperative mean of 173.3 ± 51.8 10(3)/mm(3). Compared with patients with no preoperative thrombocytopenia, patients with preoperative thrombocytopenia had an 8.69 increased odds of being in the group with postoperative platelet count <150 10(3)/mm(3). No major haemorrhagic or thromboembolic event was reported during hospitalization. This study shows that thrombocytopenia after the FS bioprosthesis replacement is a transient postoperative phenomenon, largely resolved within a few days after surgery, with no clinical consequences and haemodynamic dysfunction.
Figures
Comment in
-
eComment. platelet transfusion after aortic valve replacement by the Freedom Solo bioprosthesis.Interact Cardiovasc Thorac Surg. 2012 Apr;14(4):438-9. doi: 10.1093/icvts/ivs049. Interact Cardiovasc Thorac Surg. 2012. PMID: 22438415 Free PMC article. No abstract available.
References
-
- Beholz S, Hunter S, Alcon CA, Zussa C. Recommendations for the implantation of the Pericarbon Freedom stentless valve. Heart Surg Forum. 2005;8:E409–11. - PubMed
-
- Stacchino C, Bona G, Bonetti F, Rinaldi S, Della Ciana L, Grignani A. Detoxification process for glutaraldehyde-treated bovine pericardium: biological, chemical and mechanical characterization. J Heart Valve Dis. 1998;7:190–94. - PubMed
-
- D'Onofrio A, Auriemma S, Magagna P, Favaro A, Cannarella A, Piccin C, et al. Aortic valve replacement with the Sorin Pericarbon Freedom stentless prosthesis: 7 years' experience in 130 patients. J Thorac Cardiovasc Surg. 2007;134:491–95. - PubMed
-
- Repossini A, Kotelnikov I, Bouchikhi R, Torre T, Passaretti B, Parodi O, et al. Single-suture line placement of a pericardial stentless valve. J Thorac Cardiovasc Surg. 2005;130:1265–69. - PubMed
-
- Beholz S, Dushe S, Konertz W. The freedom solo valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement. J Heart Valve Dis. 2007;1:49–55. - PubMed
Publication types
MeSH terms
LinkOut - more resources