Abstract
Background: Double reading improves the cancer detection rate in mammography screening. Single reading with computer-aided detection (CAD) has been considered to be an alternative to double reading. Little is known about the potential benefit of CAD in breast cancer screening with double reading.
Purpose: To compare prospective independent double reading of screen-film (SFM) and full-field digital (FFDM) mammography in population-based screening with retrospective standalone CAD performance on the baseline mammograms of the screen-detected cancers and subsequent cancers diagnosed during the follow-up period.
Material and methods: The study had ethics committee approval. A 5-point rating scale for probability of cancer was used for 23,923 (SFM = 16,983; FFDM = 6940) screening mammograms. Of 208 evaluable cancers, 104 were screen-detected and 104 were subsequent (44 interval and 60 next screening round) cancers. Baseline mammograms of subsequent cancers were retrospectively classified in consensus without information about cancer location, histology, or CAD prompting as normal, non-specific minimal signs, significant minimal signs, and false-negatives. The baseline mammograms of the screen-detected cancers and subsequent cancers were evaluated by CAD. Significant minimal signs and false-negatives were considered 'actionable' and potentially diagnosable if correctly prompted by CAD.
Results: CAD correctly marked 94% (98/104) of the baseline mammograms of the screen-detected cancers (SFM = 95% [61/64]; FFDM = 93% [37/40]), including 96% (23/24) of those with discordant interpretations. Considering only those baseline examinations of subsequent cancers prospectively interpreted as normal and retrospectively categorized as 'actionable', CAD input at baseline screening had the potential to increase the cancer detection rate from 0.43% to 0.51% (P = 0.13); and to increase cancer detection by 16% ([104 + 17]/104) and decrease interval cancers by 20% (from 44 to 35).
Conclusion: CAD may have the potential to increase cancer detection by up to 16%, and to reduce the number of interval cancers by up to 20% in SFM and FFDM screening programs using independent double reading with consensus review. The influence of true- and false-positive CAD marks on decision-making can, however, only be evaluated in a prospective clinical study.
Similar articles
-
Effect of computer-aided detection on independent double reading of paired screen-film and full-field digital screening mammograms.AJR Am J Roentgenol. 2007 Feb;188(2):377-84. doi: 10.2214/AJR.05.2207. AJR Am J Roentgenol. 2007. PMID: 17242245
-
Follow-up and final results of the Oslo I Study comparing screen-film mammography and full-field digital mammography with soft-copy reading.Acta Radiol. 2005 Nov;46(7):679-89. doi: 10.1080/02841850500223547. Acta Radiol. 2005. PMID: 16372686
-
Randomized trial of screen-film versus full-field digital mammography with soft-copy reading in population-based screening program: follow-up and final results of Oslo II study.Radiology. 2007 Sep;244(3):708-17. doi: 10.1148/radiol.2443061478. Radiology. 2007. PMID: 17709826 Clinical Trial.
-
Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers.Eur J Radiol. 2015 Jun;84(6):1056-61. doi: 10.1016/j.ejrad.2015.03.007. Epub 2015 Mar 14. Eur J Radiol. 2015. PMID: 25816990 Review.
-
Studies comparing screen-film mammography and full-field digital mammography in breast cancer screening: updated review.Acta Radiol. 2009 Jan;50(1):3-14. doi: 10.1080/02841850802563269. Acta Radiol. 2009. PMID: 19037825 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous