Phosphorus liver MRSI at 3 T using a novel dual-tuned eight-channel ³¹P/¹H H coil
- PMID: 22287206
- DOI: 10.1002/mrm.24164
Phosphorus liver MRSI at 3 T using a novel dual-tuned eight-channel ³¹P/¹H H coil
Abstract
Although phosphorus-31 (³¹P) magnetic resonance spectroscopy holds potential as noninvasive tool to monitor treatment response of liver malignancies, the lack of appropriate coils has so far restricted its use to liver lesions close to the surface. A novel eight-channel phased-array dual-tuned ³¹P/¹H coil that can assess ³¹P metabolism in deeper liver tissue as well is presented in this article. Analysis of its performance demonstrates that this coil can provide good sensitivity across a width of 20 cm, thereby enabling magnetic resonance spectroscopic imaging (MRSI) scans that can fully cover axial views of the abdomen in lean subjects. In vivo results and reproducibility of ³¹P MRSI at 3 T of axial slices covering the full depth of the liver are shown in healthy volunteers. To minimize intrasubject and intersubject data variability, spectra are corrected for coil sensitivities. Methods to maximize the reproducibility of coil placement and spectroscopic planning are discussed. The phosphomonoesters/phosphodiesters ratio calculated in healthy volunteers has an average intrasubject variation of 23% averaged over voxels selected from the entire liver. Finally, the feasibility of using the coil in the clinic is shown by preliminary ³¹P liver MRSI data obtained from a patient with hepatocellular carcinoma.
Copyright © 2012 Wiley Periodicals, Inc.
Similar articles
-
(31) P MR spectroscopic imaging combined with (1) H MR spectroscopic imaging in the human prostate using a double tuned endorectal coil at 7T.Magn Reson Med. 2014 Dec;72(6):1516-21. doi: 10.1002/mrm.25070. Epub 2013 Dec 19. Magn Reson Med. 2014. PMID: 24357271
-
Computational and experimental optimization of a double-tuned (1)H/(31)P four-ring birdcage head coil for MRS at 3T.J Magn Reson Imaging. 2009 Jan;29(1):13-22. doi: 10.1002/jmri.21509. J Magn Reson Imaging. 2009. PMID: 19097097
-
Flip-angle mapping of 31P coils by steady-state MR spectroscopic imaging.J Magn Reson Imaging. 2014 Aug;40(2):391-7. doi: 10.1002/jmri.24401. Epub 2013 Nov 4. J Magn Reson Imaging. 2014. PMID: 24925600
-
Whole-body radiofrequency coil for (31) P MRSI at 7 T.NMR Biomed. 2016 Jun;29(6):709-20. doi: 10.1002/nbm.3517. Epub 2016 Apr 1. NMR Biomed. 2016. PMID: 27037615
-
Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.Invest Radiol. 2014 Jan;49(1):15-22. doi: 10.1097/RLI.0b013e3182a56678. Invest Radiol. 2014. PMID: 24019020
Cited by
-
In vivo sodium MR imaging of the abdomen at 3T.Abdom Imaging. 2015 Oct;40(7):2272-80. doi: 10.1007/s00261-015-0428-6. Abdom Imaging. 2015. PMID: 25952570 Free PMC article.
-
(31)P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results.MAGMA. 2016 Jun;29(3):579-89. doi: 10.1007/s10334-016-0524-9. Epub 2016 Jan 25. MAGMA. 2016. PMID: 26811174
-
A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T.IEEE Trans Biomed Eng. 2021 Jun;68(6):2036-2046. doi: 10.1109/TBME.2021.3063061. Epub 2021 May 21. IEEE Trans Biomed Eng. 2021. PMID: 33651680 Free PMC article.
-
Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array.Sci Rep. 2016 Jul 28;6:30568. doi: 10.1038/srep30568. Sci Rep. 2016. PMID: 27465636 Free PMC article.
-
Phosphatidylcholine contributes to in vivo (31)P MRS signal from the human liver.Eur Radiol. 2015 Jul;25(7):2059-66. doi: 10.1007/s00330-014-3578-y. Epub 2015 Jan 11. Eur Radiol. 2015. PMID: 25576233
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical