Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Nov;16(6):1351-8.
doi: 10.1016/0735-1097(90)90376-z.

Serial left ventricular performance evaluated by cardiac catheterization before, immediately after and at 6 months after balloon aortic valvuloplasty

Affiliations
Free article

Serial left ventricular performance evaluated by cardiac catheterization before, immediately after and at 6 months after balloon aortic valvuloplasty

J K Harrison et al. J Am Coll Cardiol. 1990 Nov.
Free article

Abstract

Although impaired ventricular function has been shown to improve after aortic valve replacement, there are few data on hemodynamic changes after balloon aortic valvuloplasty based on follow-up catheterization. Of 71 patients surviving 6 months after balloon aortic valvuloplasty, 41 agreed to late recatheterization. All patients had pre- and postvalvuloplasty and 6 month catheterization data measured with high fidelity micromanometer pressure recordings and simultaneous digital subtraction left ventriculography. The hemodynamic result immediately after valvuloplasty included a reduction in the aortic valve gradient and a moderate increase in aortic valve area (0.51 +/- 0.14 to 0.81 +/- 0.19 cm2, p less than 0.0001). Ejection fraction increased slightly (52 +/- 18 to 55 +/- 17%, p less than 0.0001) despite a decrease in peak positive rate of rise of left ventricular pressure (dP/dt 1,650 +/- 460 to 1,500 +/- 490 mm Hg/s, p less than 0.05). There was also a decrease in left ventricular afterload and a small decrease in preload. At 6 month recatheterization, the mean aortic valve gradient and area were similar to baseline values, with 31 (76%) of 41 patients demonstrating valvular restenosis. At 6 months many left ventricular hemodynamic variables, including peak positive dP/dt and stroke work, also resembled prevalvuloplasty values. However, left ventricular end-diastolic volume was reduced (111 +/- 40 ml at 6 months versus 136 +/- 52 ml before valvuloplasty, p less than 0.01). The mean left ventricular ejection fraction was unchanged from prevalvuloplasty values in the study group of 41 patients, but was significantly improved in 9 of 15 patients with a baseline ejection fraction less than 50%.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

LinkOut - more resources