Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Feb;14(2):132-7.
doi: 10.1007/s12094-012-0772-8.

Interobserver variability in target volume delineation in postoperative radiochemotherapy for gastric cancer. A pilot prospective study

Affiliations

Interobserver variability in target volume delineation in postoperative radiochemotherapy for gastric cancer. A pilot prospective study

Cristina Moretones et al. Clin Transl Oncol. 2012 Feb.

Abstract

Introduction: The aim of this study is to determine the interobserver variability (IV) between radiation oncologists (RO) in target volume delineation for postoperative gastric cancer (GC) radiotherapy planning.

Materials and methods: Four physicians were asked to delimitate clinical target volume (CTV) on the same 3D CT images in 9 postoperative radiochemotherapy GC patients. Instructions were given to include tumour bed, remaining stomach, anastomosis, duodenal loop and local lymph nodes. The principal variable was spatial volume discrepancy between the main observer (called "A") and other observers (all called "B"), which were compared using the mathematical formula A⌣B/A⌢B, applied to the 3D CT images using Boolean operators. Analysis of variance with two random effects (observers and patients) was performed.

Results: Mean volumes were 1410 cm(3) for OBA, 1231 cm(3) for OB2, 734.6 cm(3) for OB3 and 1350 cm(3) for OB4. Discrepancies were 519.9±431.6 cm(3) for OB2, 652.1±294.36 cm(3) for OB3 and 225.90±237.07 cm(3) for OB4. Standard deviation ascribed to patients as random effect was 898.6 cm(3) and that ascribed to observers was 198.10 cm(3), considered as a statistically significant difference.

Conclusions: A significant IV in target delineation that can be attributed to many factors depends more on patients' characteristics than RO delineating decisions.

PubMed Disclaimer

References

    1. J Appl Clin Med Phys. 2003 Autumn;4(4):365-73 - PubMed
    1. Strahlenther Onkol. 2003 Jan;179(1):21-30 - PubMed
    1. Semin Radiat Oncol. 2002 Apr;12(2):187-95 - PubMed
    1. Int J Radiat Oncol Biol Phys. 1999 Jul 1;44(4):931-5 - PubMed
    1. Br J Cancer. 2004 Jul 5;91(1):11-7 - PubMed

MeSH terms

LinkOut - more resources