Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Mar 6;125(9):1110-21.
doi: 10.1161/CIRCULATIONAHA.111.058560. Epub 2012 Feb 1.

Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents: a prospective cohort study

Affiliations
Comparative Study

Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents: a prospective cohort study

Lorenz Räber et al. Circulation. .

Abstract

Background: Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES).

Methods and results: We assessed the risk of stent thrombosis in a cohort of 12 339 patients with unrestricted use of drug-eluting stents (3819 SES, 4308 PES, 4212 EES). Results are incidence rates per 100 person-years after inverse probability of treatment weighting to adjust for group differences. During follow-up of up to 4 years, the overall incidence rate of definite stent thrombosis was lower with EES (1.4 per 100 person-years) compared with SES (2.9; hazard ratio, 0.41; 95% confidence interval, 0.27-0.62; P<0.0001) and PES (4.4; hazard ratio, 0.33; 95% confidence interval, 0.23-0.48; P<0.0001). The incidence rate per 100 person-years of early (0-30 days), late (31 days-1 year), and very late stent thrombosis amounted to 0.6, 0.1, and 0.6 among EES-treated patients; 1.0, 0.3, and 1.6 among SES-treated patients; and 1.3, 0.7, and 2.4 among PES-treated patients. Differences in favor of EES were most pronounced beyond 1 year, with a hazard ratio of 0.33 (EES versus SES; P=0.006) and 0.34 (EES versus PES; P<0.0001). There was a lower risk of cardiac death or myocardial with EES compared with PES (hazard ratio, 0.65; 95% confidence interval, 0.56-0.75; P<0.0001), which was directly related to the lower risk of stent thrombosis-associated events (EES versus PES: hazard ratio, 0.36; 95% confidence interval, 0.23-0.57).

Conclusion: Current treatment with EES is associated with a lower risk of very late stent thrombosis compared with early-generation drug-eluting stents.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources