. 1990;5(2-3):163-71.
doi: 10.1007/BF01833985.

Arterial stenting with self-expandable and balloon-expandable endoprostheses

Affiliations
Free article

Arterial stenting with self-expandable and balloon-expandable endoprostheses

W J van der Giessen et al. Int J Card Imaging. 1990.
Free article

Abstract

Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 microns in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week.

PubMed Disclaimer

Similar articles

Cited by

  • Mechanical features and in vivo imaging of a polymer stent.
    van der Giessen WJ, Slager CJ, Gussenhoven EJ, van Beusekom HM, Huijts RA, Schuurbiers JC, Wilson RA, Serruys PW, Verdouw PD. van der Giessen WJ, et al. Int J Card Imaging. 1993 Sep;9(3):219-26. doi: 10.1007/BF01145324. Int J Card Imaging. 1993. PMID: 8106801

References

    1. Invest Radiol. 1969 Sep-Oct;4(5):329-32 - PubMed
    1. J Am Coll Cardiol. 1989 Apr;13(5):1092-3 - PubMed
    1. Am J Cardiol. 1985 Nov 1;56(12):712-7 - PubMed
    1. Circulation. 1987 Aug;76(2):450-7 - PubMed
    1. Circulation. 1988 Feb;77(2):361-71 - PubMed

Publication types

Substances

LinkOut - more resources