Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode
- PMID: 22305437
- DOI: 10.1016/j.neurad.2011.12.003
Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode
Abstract
Purpose: This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STV) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI).
Methods: PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STV as well as in 10 control cases. The presence of STV was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared.
Results: There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r]=0.784; P=0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STV scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1).
Conclusion: 3D-SPACE can provide morphological-physiological information for the evaluation of STV with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Similar articles
-
Assessment of third ventriculostomy patency with the 3D-SPACE technique: a preliminary multicenter research study.J Neurosurg. 2015 Jun;122(6):1347-55. doi: 10.3171/2014.10.JNS14298. Epub 2015 Apr 10. J Neurosurg. 2015. PMID: 25859808
-
Feasibility of 3-dimensional sampling perfection with application optimized contrast sequence in the evaluation of patients with hydrocephalus.J Comput Assist Tomogr. 2015 May-Jun;39(3):321-8. doi: 10.1097/RCT.0000000000000206. J Comput Assist Tomogr. 2015. PMID: 25978590
-
Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy.J Neuroradiol. 2011 May;38(2):98-104. doi: 10.1016/j.neurad.2010.03.006. Epub 2010 Jun 7. J Neuroradiol. 2011. PMID: 20627312
-
Evaluation of hydrocephalus patients with 3D-SPACE technique using variant FA mode at 3T.Acta Neurol Belg. 2018 Jun;118(2):169-178. doi: 10.1007/s13760-017-0838-z. Epub 2017 Sep 26. Acta Neurol Belg. 2018. PMID: 28952043 Review.
-
Review of the principal extra spinal pathologies causing sciatica and new MRI approaches.Br J Radiol. 2012 Jun;85(1014):672-81. doi: 10.1259/bjr/84443179. Epub 2012 Feb 28. Br J Radiol. 2012. PMID: 22374280 Free PMC article. Review.
Cited by
-
Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences.Jpn J Radiol. 2015 Feb;33(2):94-101. doi: 10.1007/s11604-014-0385-y. Epub 2015 Jan 7. Jpn J Radiol. 2015. PMID: 25559932
-
Spontaneous third ventriculostomy 8 years after diagnosis of obstructive hydrocephalus.Childs Nerv Syst. 2016 Sep;32(9):1727-30. doi: 10.1007/s00381-016-3096-0. Epub 2016 Apr 23. Childs Nerv Syst. 2016. PMID: 27107889 Review.
-
Evaluation of aqueductal patency in patients with hydrocephalus: three-dimensional high-sampling-efficiency technique (SPACE) versus two-dimensional turbo spin echo at 3 Tesla.Korean J Radiol. 2014 Nov-Dec;15(6):827-35. doi: 10.3348/kjr.2014.15.6.827. Epub 2014 Nov 7. Korean J Radiol. 2014. PMID: 25469096 Free PMC article.
-
Case report: Flattening of the tectal plate in obstructive hydrocephalus with auto-ventriculostomy.Neuroradiol J. 2022 Apr;35(2):255-259. doi: 10.1177/19714009211036686. Epub 2021 Aug 2. Neuroradiol J. 2022. PMID: 34340619 Free PMC article.
-
Prediction of endoscopic third ventriculostomy (ETV) success with 3D-SPACE technique.Neurosurg Rev. 2015 Apr;38(2):395-7. doi: 10.1007/s10143-014-0604-0. Epub 2014 Dec 17. Neurosurg Rev. 2015. PMID: 25512218 No abstract available.