Reliability of the visual analog scale in children with acute pain in the emergency department
- PMID: 22305630
- DOI: 10.1016/j.pain.2012.01.006
Reliability of the visual analog scale in children with acute pain in the emergency department
Abstract
In children, many psychometric properties of the visual analogue scale (VAS) are known, including the minimum clinically significant difference (10mm on a 100-mm VAS). However, its imprecision or reliability is not well known. Thus, in order to determine the reliability of this scale, a prospective cohort study was performed in patients aged 8-17 years presenting to a pediatric emergency department with acute pain. Pain was graded 4 times using a paper VAS (0-100mm): T(0), T(3), T(6), and T(≥ 36)minutes. After T(6), patients were asked if their pain had changed since T(0)minute. The primary analysis was the repeatability coefficient of the VAS, determined according to the Bland-Altman method for measuring agreement using repeated measures in patients reporting that their pain was the same for T(0), T(3), and T(6). In order to appropriately estimate the within-subject SD, 96 patients were required if we obtained 3 measurements for each patient. A total of 151 patients with a mean age of 12.2 ± 2.5 years were enrolled. Among them, 100 mentioned that their pain was the same for T(0), T(3), and T(6)minutes. The repeatability coefficient of the VAS for these children was 12 mm when the pain did not change. This implies that, for a child, all pain intensity measurements within 12 mm should be considered the same pain intensity on a paper VAS. This measure should also be evaluated on other types of VAS.
Copyright © 2012 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
References
-
- Bijur PE, Silver W, Gallagher EJ. Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med. 2001;8:1153-1157.
-
- Bland J, Altman M. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160.
-
- Bland J, Altman M. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet. 1986;1:307-317.
-
- Bland J, Altman M. Measurement error. BMJ. 1996;313:744.
-
- DeLoach L, Higgins M, Caplan A, Stiff J. The visual analog scale in the immediate postoperative period: intrasubject variability and correlation with a numeric scale. Anesth Analg. 1998;86:102-106.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical