Rib cage and abdominal piezoelectric film belts to measure ventilatory airflow
- PMID: 2230857
- DOI: 10.1007/BF02842487
Rib cage and abdominal piezoelectric film belts to measure ventilatory airflow
Abstract
Piezoelectric film-based respiratory belts are described and tested. To the extent that a two-degree of freedom model consisting of rib cage and abdominal motion is able to assist in quantifying ventilation, the piezoelectric belts can monitor flow in a manner analogous to the monitoring of volume with two magnetometer pairs or two respiratory inductive plethysmograph belts. The piezoelectric belts are shown to measure flow linearly when compared with a screen pneumotachometer to a flow of at least 2.6 L/s. There is no phase shift between the peak flow of belts and the pneumotachometer up to a frequency of at least 9.2 Hz. During normal ventilation, 68 and 95% of the peak flows measured with the belts fall within +/- 10 and 20%, respectively, of the flows measured with a screen pneumotachometer.
Similar articles
-
A piezoelectric respiratory monitor for in vivo NMR.Magn Reson Med. 1992 Oct;27(2):338-42. doi: 10.1002/mrm.1910270213. Magn Reson Med. 1992. PMID: 1461117
-
Spatial distribution of human respiratory system transfer impedance.Ann Biomed Eng. 2003 Feb;31(2):121-31. doi: 10.1114/1.1541012. Ann Biomed Eng. 2003. PMID: 12627819 Clinical Trial.
-
Design of an inductive plethysmograph for ventilation measurement.Physiol Meas. 1994 May;15(2):217-29. doi: 10.1088/0967-3334/15/2/009. Physiol Meas. 1994. PMID: 8081197
-
Estimation of respiratory variables from thoracoabdominal breathing distance: a review of different techniques and calibration methods.Physiol Meas. 2019 Apr 3;40(3):03TR01. doi: 10.1088/1361-6579/ab0b63. Physiol Meas. 2019. PMID: 30818285 Review.
-
[Optoelectronic plethysmography -- a new technic to measure changes of chest wall volume].Pneumonol Alergol Pol. 2007;75(1):81-7. Pneumonol Alergol Pol. 2007. PMID: 17541916 Review. Polish.
Cited by
-
Improved regression models for ventilation estimation based on chest and abdomen movements.Physiol Meas. 2012 Jan;33(1):79-93. doi: 10.1088/0967-3334/33/1/79. Physiol Meas. 2012. PMID: 22173273 Free PMC article.
-
Descriptive ventilatory mechanics from noninvasive analog display of ribcage and abdominal flow.Ann Biomed Eng. 1992;20(5):559-72. doi: 10.1007/BF02368174. Ann Biomed Eng. 1992. PMID: 1416291
-
Tissue artifact removal from respiratory signals based on empirical mode decomposition.Ann Biomed Eng. 2013 May;41(5):1003-15. doi: 10.1007/s10439-013-0742-5. Epub 2013 Jan 17. Ann Biomed Eng. 2013. PMID: 23325303 Free PMC article.
References
MeSH terms
LinkOut - more resources
Other Literature Sources