Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Dec;77(6):802-8.

The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures

Affiliations
  • PMID: 22308627

The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures

Jordanna M Forman et al. Acta Orthop Belg. 2011 Dec.

Abstract

The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This study suggests that the use of percutaneous clamps during intramedullary nailing of distal metaphyseal tibia fractures is an easily-reproducible and effective method of reduction with no associated intraoperative complications.

PubMed Disclaimer