Optimisation and validation of a quantitative and confirmatory method for residues of macrolide antibiotics and lincomycin in kidney by liquid chromatography coupled to mass spectrometry
- PMID: 22320663
- DOI: 10.1080/19440049.2011.652196
Optimisation and validation of a quantitative and confirmatory method for residues of macrolide antibiotics and lincomycin in kidney by liquid chromatography coupled to mass spectrometry
Abstract
A solid phase extraction followed by a liquid chromatography (LC)-tandem mass spectrometry (MS/MS) detection method for the confirmatory analysis of lincomycin (LIN), clindamycin (CLI), tilmicosin (TIM), erythromycin (ERI) and tylosin (TYL) residues in kidney were optimised and validated for monitoring and controlling the use of these antibiotics in food producing-animals. The method optimisation was carried out by testing changes in the extraction buffer pH and in the ammonium/acetonitrile concentrations on SPE eluent solutions. The optimised extraction procedure involved the extraction of the analytes with a pH 8 phosphate buffer, clean-up on a reversed-phase mixed-cation exchange cartridge, followed by the elution of the analytes in a 98:2 acetonitrile/ammonia solution, concentration in air flow and re-dissolved with an 1:1 methanol/water solution. The analytes were detected in an LC-MS/MS system in electrospray positive ionisation mode. The validation was performed according to the European Commission Decision 2002/657/EC. Linearity was established for all analytes using the method of least weighted squares and CCα values ranged from 5.3% to 21.1% higher than the minimum residue limit (MRL) values. The addition levels varied from 0.5 to 1.50 MRL for all analytes, with recoveries exceeding 92.5%. The relative standard deviations (RSD%) in terms of repeatability (n = 54) and reproducibility (n = 108) for all analytes were less than 21.6% and 21.4%, respectively. The uncertainties were calculated by simplified methods using the calibration curve uncertainty and the intermediate precision to obtain the combined measurement uncertainty. The results of the validation process demonstrated that this method is suitable for the quantification and confirmation of antibiotic residues for the Brazilian Residue and Contaminant Control Plan (PNCR).
Similar articles
-
Validation of a quantitative and confirmatory method for residue analysis of aminoglycoside antibiotics in poultry, bovine, equine and swine kidney through liquid chromatography-tandem mass spectrometry.Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2012;29(4):517-25. doi: 10.1080/19440049.2011.623681. Epub 2011 Nov 8. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2012. PMID: 22059623
-
Optimisation and validation of a quantitative and confirmatory LC-MS method for multi-residue analyses of β-lactam and tetracycline antibiotics in bovine muscle.Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2012;29(4):541-9. doi: 10.1080/19440049.2011.627883. Epub 2011 Nov 10. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2012. PMID: 22070766
-
A simple and rapid confirmatory assay for analyzing antibiotic residues of the macrolide class and lincomycin in bovine milk and yoghurt: hot water extraction followed by liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2007;21(2):237-46. doi: 10.1002/rcm.2835. Rapid Commun Mass Spectrom. 2007. PMID: 17171776
-
Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.Mass Spectrom Rev. 2009 Jan-Feb;28(1):50-92. doi: 10.1002/mas.20189. Mass Spectrom Rev. 2009. PMID: 18785191 Review.
-
The use of ultra-high pressure liquid chromatography with tandem mass spectrometric detection in the analysis of agrochemical residues and mycotoxins in food - challenges and applications.J Chromatogr A. 2013 May 31;1292:83-95. doi: 10.1016/j.chroma.2013.01.007. Epub 2013 Jan 9. J Chromatogr A. 2013. PMID: 23352828 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical
Research Materials
Miscellaneous