Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Mar 15;53(3):1414-21.
doi: 10.1167/iovs.11-8808.

Femtosecond lenticule extraction (FLEx): clinical results, interface evaluation, and intraocular pressure variation

Affiliations

Femtosecond lenticule extraction (FLEx): clinical results, interface evaluation, and intraocular pressure variation

Marcus Ang et al. Invest Ophthalmol Vis Sci. .

Abstract

Purpose: To characterize the clinical profile of femtosecond lenticule extraction (FLEx) correlated with ultrastructural analysis of the corneal interface and in vivo real-time intraocular pressure (IOP).

Methods: Prospective clinical case series with experimental studies; consecutive patients underwent FLEx at a single tertiary center over 10 months with postsurgical follow-up of 3 months. The patients were divided into three groups according to spherical equivalence (SE) (A, < -5.0 diopters [D]; B, ≥ -5.00 D and < -9.00 D; and C, ≥ -9.0 D). Twelve human cadaveric eyes analyzed using scanning electron microscopy after receiving FLEx; 40 rabbit eyes received FLEx with in vivo IOP measurements. The main outcome measures were refractive outcomes from study subjects; with corneal interface and IOP in experimental studies.

Results: Thirty-three subjects (22 females, 66.7%) underwent FLEx in both eyes (66 eyes). Mean age was 32 years (range, 21 to 46 years). Preoperative mean SE was -5.77 ± 2.04 D with astigmatism of -1.03 ± 0.72 D. There was a slight hyperopic shift (mean SE 0.14 ± 0.53 D); 94% achieved uncorrected visual acuity ≥20/25 3 months postoperatively. Refractive stability was achieved within 1 month (P < 0.001). Ultrastructurally, the smoothness of the corneal interface was independent of ablation depth (mean irregularity scores A, B, C: 8.8 ± 0.6, 10.3 ± 0.4, 8.7 ± 0.6, respectively; P = 0.88). The increase in IOP during FLEx was similar to that in femtosecond (FS)-LASIK, albeit a twofold duration of raised IOP in FLEx (P < 0.001).

Conclusions: These results suggest that FLEx is predictable and effective in treating myopia and myopic astigmatism. Experimental studies support the early clinical results and safety of this procedure.

PubMed Disclaimer

Publication types

MeSH terms