Single-exposure dual-energy computed radiography
- PMID: 2233574
- DOI: 10.1118/1.596479
Single-exposure dual-energy computed radiography
Abstract
This paper focuses on analysis and development of a single-exposure dual-energy digital radiographic method using computed radiography (Fuji FCR-101 storage phosphor system). A detector sandwich consisting of storage phosphor imaging plates and an interdetector filter is used. The goal of this process is to provide a simple dual-energy method using typical plane-projection radiographic equipment and techniques. This approach exploits the transparency of the storage phosphor plates, using radiographic information that would be otherwise lost, to provide energy selective information essentially as a by-product of the radiographic examination. In order to effectively make use of the large dynamic range of the storage phosphor imaging plates (10,000:1), a computed radiography image reading mode of fixed analog-to-digital converter gain and variable photomultiplier sensitivity provides image data which can be related to relative incident exposure for export to the decomposition algorithm. Scatter rejection requirements necessitated crossed 12:1 grids for a field size of 36 x 36 cm. Optimal technique parameters obtained from computer simulation through minimization of the aluminum and Plexiglas equivalent image uncertainty under conditions of constant absorbed does resulted as: 100 kVp using a 0.15-mm-thick tin (Sn) interdetector filter for the lung field. This yields a surface exposure of 23 mR and a surface absorbed dose of 0.26 mGy for a 23-cm-thick chest. Clinical application in evaluation of the solitary pulmonary nodule is discussed, along with an image set demonstrating this application.
Similar articles
-
Clinical application of single dual-energy subtraction technique with digital storage-phosphor radiography.J Digit Imaging. 1995 Feb;8(1 Suppl 1):21-4. doi: 10.1007/BF03168062. J Digit Imaging. 1995. PMID: 7734535
-
Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.Phys Med Biol. 2007 Jan 7;52(1):183-96. doi: 10.1088/0031-9155/52/1/012. Epub 2006 Dec 14. Phys Med Biol. 2007. PMID: 17183135
-
[Digital radiography: from storage phosphor plates to direct detector systems].Wien Med Wochenschr Suppl. 2002;(113):30-4. Wien Med Wochenschr Suppl. 2002. PMID: 12621834 German.
-
Quality control of storage phosphor digital radiography systems.J Digit Imaging. 1995 May;8(2):67-74. doi: 10.1007/BF03168129. J Digit Imaging. 1995. PMID: 7612704 Review.
-
[New analog and digital imaging techniques for chest diagnosis--principles--clinical value--economics].Aktuelle Radiol. 1993 Jan;3(1):6-13. Aktuelle Radiol. 1993. PMID: 8448232 Review. German.
Cited by
-
Comparison of three tissue composition measurement techniques using digital mammograms--a signal-to-noise study.J Digit Imaging. 1998 Aug;11(3):137-50. doi: 10.1007/BF03168737. J Digit Imaging. 1998. PMID: 9718504 Free PMC article.
-
Improvement of detection in computed radiography by new single-exposure dual-energy subtraction.J Digit Imaging. 1993 Feb;6(1):42-7. doi: 10.1007/BF03168417. J Digit Imaging. 1993. PMID: 8439582
-
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.Radiology. 2015 Sep;276(3):637-53. doi: 10.1148/radiol.2015142631. Radiology. 2015. PMID: 26302388 Free PMC article. Review.
-
Biplane correlation imaging: a feasibility study based on phantom and human data.J Digit Imaging. 2012 Feb;25(1):137-47. doi: 10.1007/s10278-011-9392-z. J Digit Imaging. 2012. PMID: 21618054 Free PMC article.
-
Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice.Eur Radiol. 2008 Jan;18(1):24-31. doi: 10.1007/s00330-007-0758-z. Epub 2007 Sep 27. Eur Radiol. 2008. PMID: 17899105
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources