An adaptive single-well stochastic resonance algorithm applied to trace analysis of clenbuterol in human urine
- PMID: 22337140
- PMCID: PMC6268344
- DOI: 10.3390/molecules17021929
An adaptive single-well stochastic resonance algorithm applied to trace analysis of clenbuterol in human urine
Abstract
Based on the theory of stochastic resonance, an adaptive single-well stochastic resonance (ASSR) coupled with genetic algorithm was developed to enhance the signal-to-noise ratio of weak chromatographic signals. In conventional stochastic resonance algorithm, there are two or more parameters needed to be optimized and the proper parameters values were obtained by a universal searching within a given range. In the developed ASSR, the optimization of system parameter was simplified and automatic implemented. The ASSR was applied to the trace analysis of clenbuterol in human urine and it helped to significantly improve the limit of detection and limit of quantification of clenbuterol. Good linearity, precision and accuracy of the proposed method ensure that it could be an effective tool for trace analysis and the improvement of detective sensibility of current detectors.
Figures



Similar articles
-
Quantification of clenbuterol at trace level in human urine by ultra-high pressure liquid chromatography-tandem mass spectrometry.J Chromatogr A. 2013 May 31;1292:142-50. doi: 10.1016/j.chroma.2012.12.008. Epub 2012 Dec 19. J Chromatogr A. 2013. PMID: 23294994
-
Detection of clenbuterol at trace levels in doping analysis using different gas chromatographic-mass spectrometric techniques.J Chromatogr Sci. 2013 May-Jun;51(5):436-45. doi: 10.1093/chromsci/bms160. Epub 2012 Oct 5. J Chromatogr Sci. 2013. PMID: 23042839
-
Sensitive and Matrix-Tolerant Lateral Flow Immunoassay Based on Fluorescent Magnetic Nanobeads for the Detection of Clenbuterol in Swine Urine.J Agric Food Chem. 2019 Mar 13;67(10):3028-3036. doi: 10.1021/acs.jafc.8b06449. Epub 2019 Mar 4. J Agric Food Chem. 2019. PMID: 30793901
-
Gas chromatography-mass spectrometric analysis of clenbuterol from urine.J Pharm Biomed Anal. 1998 Dec;18(4-5):639-44. doi: 10.1016/s0731-7085(98)00284-2. J Pharm Biomed Anal. 1998. PMID: 9919964
-
Improving the detection sensitivity of chromatography by stochastic resonance.Analyst. 2014 May 7;139(9):2099-107. doi: 10.1039/c3an02192k. Analyst. 2014. PMID: 24622614 Review.
Cited by
-
Controlled Symmetry with Woods-Saxon Stochastic Resonance Enabled Weak Fault Detection.Sensors (Basel). 2023 May 25;23(11):5062. doi: 10.3390/s23115062. Sensors (Basel). 2023. PMID: 37299789 Free PMC article.
-
The application of multiobjective genetic algorithm to the parameter optimization of single-well potential stochastic resonance algorithm aimed at simultaneous determination of multiple weak chromatographic peaks.ScientificWorldJournal. 2014 Jan 12;2014:767018. doi: 10.1155/2014/767018. eCollection 2014. ScientificWorldJournal. 2014. PMID: 24526920 Free PMC article.
References
-
- Permann D.N.S., Teitelbaum H. Wavelet fast Fourier transform (WFFT) analysis of a millivolt signal for a transient oscillating chemical reaction. J. Phys. Chem. 1993;97:12670–12673. doi: 10.1021/j100151a007. - DOI
-
- Muddiman D.C., Huang B.M., Anderson G.A., Rockwood A., Hofstadler S.A., Weir-Lipton M.S., Proctor A., Qinyuan W., Smith R.D. Application of sequential paired covariance to liquid chromatography-mass spectrometry data Enhancements in both the signal-to-noise ratio and the resolution of analyte peaks in the chromatogram. J. Chromatogr. A. 1997;771:1–7. doi: 10.1016/S0021-9673(97)00069-1. - DOI
-
- Vivó-Truyols G., Schoenmakers P.J. Automatic selection of optimal Savitzky-Golay smoothing. Anal. Chem. 2006;78:4598–4608. - PubMed
-
- Pan Z., Guo W., Wu X., Cai W., Shao S. A new stochastic resonance algorithm to improve the detection limits for trace analysis. Chemom. Intell. Lab. Syst. 2003;66:41–49. doi: 10.1016/S0169-7439(03)00003-0. - DOI
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources