Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jul;64(7):1011-9.
doi: 10.1002/acr.21644.

Is ultrasound a validated imaging tool for the diagnosis and management of synovitis in juvenile idiopathic arthritis? A systematic literature review

Affiliations
Free article

Is ultrasound a validated imaging tool for the diagnosis and management of synovitis in juvenile idiopathic arthritis? A systematic literature review

Paz Collado et al. Arthritis Care Res (Hoboken). 2012 Jul.
Free article

Abstract

Objective: Ultrasound (US) has been shown to be a sensitive tool for evaluating synovitis in rheumatoid arthritis. However, the validity of US has not yet been established in juvenile idiopathic arthritis (JIA). The purpose of this study was to assess the validity of US for detecting synovitis for both diagnosis and followup in JIA.

Methods: A systematic literature search in Embase and PubMed was performed before February 25, 2011. Selection criteria included original articles on children, JIA, US, Doppler, synovitis, and management published in the English language. Data were extracted from the articles meeting the inclusion criteria, particularly those focused on the US definition of synovitis, scoring systems used, and metric properties studied. The type and number of joints tested, study design, and quality of the studies were assessed.

Results: Twenty studies were identified using US to assess synovitis in JIA. The knee was the joint most commonly studied in these articles. There was heterogeneity regarding the US definition and quantification of synovitis. Synovitis was commonly assessed by using gray scale and only a few studies included the Doppler technique. Construct validity was reported in 80% of articles, including the clinical examination as the main comparator. US demonstrated higher sensitivity in detecting synovitis as compared to clinical examination. Few studies reported US reliability and responsiveness in JIA.

Conclusion: US is a valuable tool for detecting synovitis in JIA, and demonstrated higher sensitivity in assessing synovitis as compared to clinical examination. However, further studies are needed for evaluating the reliability and responsiveness to assess synovitis changes over time.

PubMed Disclaimer

Publication types

LinkOut - more resources