Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul-Sep;22(3):106-9.

Exchange nailing for non-union of femoral shaft fractures

Affiliations
  • PMID: 22338431

Exchange nailing for non-union of femoral shaft fractures

Mohammad Naeem-ur-Razaq et al. J Ayub Med Coll Abbottabad. 2010 Jul-Sep.

Abstract

Background: There are many ways to treat aseptic non-union of femoral shaft fractures with reported varied success rate. Amongst all these, Exchange nailing is the simplest and most successful technique for treating aseptic non union of femoral shaft fractures. We have carried out a prospective study in the Department of Trauma & Orthopaedics, Ayub Medical College Abbottabad to analyse the role of exchange nailing for aseptic non union of femoral shaft fractures.

Methods: Forty-three femoral shaft aseptic non-unions in 41 consecutive patients were treated using exchange IM nailing, from January 2006 to December 2007. The inclusion criteria for patients in the study was a femoral shaft fractures aseptic non-union, has less than 1 Cm shortening with no segmental bone defect, and a radiolucent line of the non-union, and which had previously been treated by intra-medullary nail. The surgical technique included removal of previously inserted intra-medullary nail, reaming of medullary cavity up to 2 mm above the previous size, and re-insertion of statically locked exchange intra-medullary nail.

Results: Forty-three femoral shaft aseptic non-union in 41 patients were treated; the mean age of the patients was 38.81 +/- 13.75 years. Thirty-nine non-union out of total 43 cases (39/43) had healed giving a union rate of 90%. Non-union persisted in the remaining four cases (4/43) in-spite of extended post operative follow up of these patients for 18 months. Mean union was 4.97 +/- 1.53 months. No major surgical complications were noted.

Conclusion: Exchange nailing is a simple technique for treating aseptic non union of femoral shaft fractures. Based on the results of our study, we recommend it as the procedure of choice for non comminuted, aseptic non union of femoral shaft fracture.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources