Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 May 1;109(9):1288-94.
doi: 10.1016/j.amjcard.2011.12.019. Epub 2012 Feb 15.

Safety and efficacy of the XIENCE V everolimus-eluting stent compared to first-generation drug-eluting stents in contemporary clinical practice

Affiliations
Randomized Controlled Trial

Safety and efficacy of the XIENCE V everolimus-eluting stent compared to first-generation drug-eluting stents in contemporary clinical practice

Ron Waksman et al. Am J Cardiol. .

Abstract

Data from randomized clinical trials have shown the safety and efficacy of the XIENCE V in selected populations. However, limited data are available comparing the XIENCE V to the first-generation CYPHER sirolimus-eluting stent. This study aimed to assess the long-term safety and clinical efficacy of the XIENCE V everolimus-eluting stent compared to first-generation stents in an unselected patient population. This retrospective analysis included 6,069 patients treated with CYPHER, TAXUS, and XIENCE stents from 2003 to 2009 at our institution. The patients were followed up for ≥1 year after the index procedure. The baseline characteristics were generally comparable among the 3 groups, with the exception of a significantly greater prevalence of diabetes mellitus, systemic hypertension, and a history of angioplasty and coronary bypass surgery among the XIENCE patients. The XIENCE patients also had a twofold greater rate of type C lesions. One-year follow-up data were available for 82% of the patients. The 1-year major adverse cardiovascular events rate was 9.3% for the XIENCE stent versus 9.8% for the CYPHER stent and 11.5% for the TAXUS stent (p = 0.11). Mortality was lower in the XIENCE group than in the CYPHER and TAXUS groups (3.6% vs 4.9% vs 7.2%, respectively, p <0.001), and target lesion revascularization was similar (5.9% vs 5.2% vs 5.6%, respectively; p = 0.34). Stent thrombosis was lower in the XIENCE patients (0.2% vs 1.2% vs 0.7%, p = 0.007). In conclusion, in a contemporary United States clinical practice with an unselected patient population, use of the XIENCE V stent was associated with an improved safety profile and reduction of all-cause mortality and stent thrombosis compared to first-generation drug-eluting stents. The XIENCE V failed to demonstrate superiority for overall major adverse cardiovascular events, Q-wave myocardial infarction, and revascularization rates.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources