Comparison of oligonucleotide-labeled antibody probe assays for prostate-specific antigen detection
- PMID: 22343190
- DOI: 10.1016/j.ab.2012.02.004
Comparison of oligonucleotide-labeled antibody probe assays for prostate-specific antigen detection
Abstract
As a specific tumor marker, prostate-specific antigen (PSA) is widely used for the early diagnosis of prostate cancer. Sensitive and specific methods are required to improve the diagnostic accuracy of PSA detection. In the current study, we compared the immuno-polymerase chain reaction (immuno-PCR) method with the solid-phase proximity ligation assay (SP-PLA) with respect to the detection of PSA. Using oligonucleotide-labeled antibody probes, we used both immuno-PCR and SP-PLA to detect trace levels of PSA. The nucleic acid sequences can be monitored using real-time PCR. SP-PLA, however, was found to be superior in terms of both the detection limit and the dynamic range. To detect even lower levels of PSA, we used the loop-mediated isothermal amplification (LAMP) method to measure the levels of reporter DNA molecules in SP-PLA. The sensitivity of the LAMP method is 0.001 pM, which is approximately 100-fold higher than the sensitivities of the other assays. The results suggest that an SP-PLA- and LAMP-based protocol with oligonucleotide-labeled antibody probes may have great application in detecting PSA or other proteins present at trace levels.
Copyright © 2012 Elsevier Inc. All rights reserved.
Similar articles
-
A sensitive proximity ligation assay for active PSA.Biol Chem. 2006 Jun;387(6):769-72. doi: 10.1515/BC.2006.096. Biol Chem. 2006. PMID: 16800738
-
Reverse transcriptase polymerase chain reaction for prostate specific antigen in the management of prostate cancer.J Urol. 1997 Aug;158(2):326-37. J Urol. 1997. PMID: 9224297 Review.
-
Development and evaluation of three real-time immuno-PCR assemblages for quantification of PSA.J Immunol Methods. 2005 Sep;304(1-2):107-16. doi: 10.1016/j.jim.2005.06.015. J Immunol Methods. 2005. PMID: 16111699
-
Detection of circulating gastric carcinoma-associated antigen MG7-Ag in human sera using an established single determinant immuno-polymerase chain reaction technique.Cancer. 2000 Jan 15;88(2):280-5. Cancer. 2000. PMID: 10640958
-
Review on the simultaneous determination of total prostate-specific antigen and free prostate-specific antigen.Prostate Suppl. 1996;7:48-57. Prostate Suppl. 1996. PMID: 8950364 Review.
Cited by
-
Nanomaterial-based biosensors for detection of prostate specific antigen.Mikrochim Acta. 2017 Jul 14;184(9):3049-3067. doi: 10.1007/s00604-017-2410-1. Mikrochim Acta. 2017. PMID: 29109592 Free PMC article. Review.
-
Protein analytical assays for diagnosing, monitoring, and choosing treatment for cancer patients.J Healthc Eng. 2012 Dec;3(4):503-534. doi: 10.1260/2040-2295.3.4.503. J Healthc Eng. 2012. PMID: 25147725 Free PMC article.
-
Proximity assays for sensitive quantification of proteins.Biomol Detect Quantif. 2015 May 20;4:10-6. doi: 10.1016/j.bdq.2015.04.002. eCollection 2015 Jun. Biomol Detect Quantif. 2015. PMID: 27077033 Free PMC article. Review.
-
Challenges in Detection of Serum Oncoprotein: Relevance to Breast Cancer Diagnostics.Breast Cancer (Dove Med Press). 2021 Oct 14;13:575-593. doi: 10.2147/BCTT.S331844. eCollection 2021. Breast Cancer (Dove Med Press). 2021. PMID: 34703307 Free PMC article. Review.
-
An ultrasensitive flow cytometric immunoassay based on bead surface-initiated template-free DNA extension.Chem Sci. 2018 Jul 23;9(32):6605-6613. doi: 10.1039/c8sc02752h. eCollection 2018 Aug 28. Chem Sci. 2018. PMID: 30310592 Free PMC article.