Outcome of periprosthetic distal femoral fractures following knee arthroplasty
- PMID: 22348954
- DOI: 10.1016/j.injury.2012.01.025
Outcome of periprosthetic distal femoral fractures following knee arthroplasty
Abstract
Introduction: The majority of periprosthetic fractures around the knee occur at the supracondylar region of the distal femur. Fixation of distal femoral fractures in osteoporotic bone with short segment remains a challenge, especially after total knee arthroplasty (TKA). Internal fixation of these fractures using locking plates has become popular. The purpose of this study was to evaluate a consecutive series of periprosthetic supracondylar femoral fractures treated with locked periarticular plate fixation with regard to surgical procedure, complications and clinical outcome.
Materials and methods: From two academic trauma centres, 55 consecutive periprosthetic distal femoral fractures (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association, AO/OTA 33) were retrospectively identified as having been treated with locked plate fixation. Of these, 36 fractures in 35 patients (86.1% female) met the inclusion criteria. Patients had an average age of 73.2 years (range 54-95 years). Fixation constructs for plate length and working length were delineated. Nonunion, infection and implant failure were used as complication variables. Demographics were assessed. Outcome was addressed radiographically and clinically according to Kristensen et al.(1) by range of motion and pain.
Results: Twenty-five of 36 fractures (69.4%) healed after the index procedure. Eight of 36 fractures (22.2%) developed a nonunion with three fractures (8.3%) leading to hardware failure. Nine of the 36 patients (25%) were radiographically diagnosed with notching of the anterior femoral cortex. Regarding technical aspects, distance from the anterior flange of the femoral component to fracture was significantly shorter in patients with compared to without anterior notching (t=3.68, p=0.02). Patients who underwent submuscular plate insertion compared to an extensive lateral approach had a reduced nonunion risk (χ(2)=0.05). No difference in infection rate was found for submuscular procedures compared with open procedures (χ(2)=0.85). Range of motion was reduced in most of the patients and 13.5% had a persistent loss of extension of 5°. More than 77% of the patients reported no or only mild pain during the last office visit. Range of motion loss did not influence pain. Successful treatment according to Cain et al.(2) was achieved in 83%. Using Kristensen's(1) criteria, 56% of the knees had acceptable flexion.
Conclusion: Operative fixation of periprosthetic distal femoral fractures after TKA continues to be challenging. Notching of the anterior femoral cortex should be avoided. Loss of reduction and high failure rates still occur with locked plating and may be related to underlying factors. Indirect reduction and submuscular plate insertion technique reduce nonunion risk.
Copyright © 2012 Elsevier Ltd. All rights reserved.
Similar articles
-
Clinical outcome of interprosthetic femoral fractures treated with polyaxial locking plates.Injury. 2016 Apr;47(4):934-8. doi: 10.1016/j.injury.2015.12.026. Epub 2016 Jan 2. Injury. 2016. PMID: 26792022
-
[Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].Acta Chir Orthop Traumatol Cech. 2009 Dec;76(6):473-8. Acta Chir Orthop Traumatol Cech. 2009. PMID: 20067694 Czech.
-
Locked plating of periprosthetic femur fractures above total knee arthroplasty.J Orthop Trauma. 2012 Jul;26(7):427-32. doi: 10.1097/BOT.0b013e31822c050b. J Orthop Trauma. 2012. PMID: 22357080
-
Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis.Knee Surg Sports Traumatol Arthrosc. 2017 Sep;25(9):2921-2928. doi: 10.1007/s00167-016-4050-0. Epub 2016 Feb 20. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 26897137 Review.
-
Periprosthetic Distal Femur Fracture after Total Knee Arthroplasty: A Systematic Review.Orthop Surg. 2015 Nov;7(4):297-305. doi: 10.1111/os.12199. Orthop Surg. 2015. PMID: 26790831 Free PMC article.
Cited by
-
Retrograde Intramedullary Nailing and Locked Plating for the Treatment of Periprosthetic Supracondylar Femur Fractures: A Meta-Analysis and Quantitative Review.Arch Bone Jt Surg. 2022 May;10(5):395-402. doi: 10.22038/ABJS.2021.57246.2839. Arch Bone Jt Surg. 2022. PMID: 35755784 Free PMC article. Review.
-
Clinical outcomes in periarticular knee fractures with flexible fixation using far cortical locking screws in locking plate: a prospective study.Musculoskelet Surg. 2019 Aug;103(2):149-153. doi: 10.1007/s12306-018-0553-9. Epub 2018 Jul 2. Musculoskelet Surg. 2019. PMID: 29968233
-
Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods.Knee Surg Sports Traumatol Arthrosc. 2014 Nov;22(11):2690-7. doi: 10.1007/s00167-013-2572-2. Epub 2013 Jun 22. Knee Surg Sports Traumatol Arthrosc. 2014. PMID: 23794003
-
DXA evaluation of femoral bone mineral density and cortical width in patients with prior total knee arthroplasty.Osteoporos Int. 2019 Feb;30(2):383-390. doi: 10.1007/s00198-018-4682-7. Epub 2018 Aug 31. Osteoporos Int. 2019. PMID: 30171301
-
Distal Femoral Replacement Following an Intraoperative Periprosthetic Fracture in a Patient with Prior Bone Mulch ACL Reconstruction.Case Rep Orthop. 2019 Mar 31;2019:6213807. doi: 10.1155/2019/6213807. eCollection 2019. Case Rep Orthop. 2019. PMID: 31049236 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous