Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 May;50(5):1141-7.
doi: 10.1016/j.bone.2012.02.003. Epub 2012 Feb 12.

Reference intervals of bone turnover markers in healthy premenopausal women: results from a cross-sectional European study

Affiliations

Reference intervals of bone turnover markers in healthy premenopausal women: results from a cross-sectional European study

Richard Eastell et al. Bone. 2012 May.

Abstract

Robust validated reference intervals for bone turnover markers (BTMs) are required to assess fracture risk and effectiveness of therapy. However, there are currently limited reference intervals for BTMs in premenopausal women, especially comparing manual and automated assays. This study determined the BTM reference intervals using automated and manual assays, compared the results obtained from two different assays, and evaluated the factors that may affect BTM levels. This was a cross-sectional registry study in 194 healthy, premenopausal, European Caucasian women aged 35 to 39years from France (n=98) and Denmark (n=96). Two independent specialized laboratories, one in France (Synarc) and the other in Denmark (Nordic Bioscience), analyzed blood and urine samples from each woman for BTM levels. The type of assay used in this study significantly affected the reference intervals obtained for serum cross-linked C-terminal telopeptide of type I collagen (sCTX) and urinary cross-linked N-terminal telopeptides of type I collagen (uNTX/Cr; both P<0.001), but not for serum procollagen type I amino-terminal propeptide (PINP; P=0.28). The Serum Crosslaps® ELISA; Microtitre-plate based ELISA; Metra BAP EIA; and UniQ® PINP RIA assays yielded higher BTM reference values. The reference intervals for the BTMs, as measured with Serum β-Crosslaps, Elecsys® 2010 Systems; VITROS® ECI System; Ostase®, Access® Immunoassay System; and Total PINP, Elecsys® 2010 Systems assays, were 0.111-0.791ng/mL for sCTX, 12.3-59.7nmol BCE/mmol creatinine for uNTX/Cr, 5.8-17.5ng/mL for bone alkaline phosphatase (ALP), and 17.3-83.4ng/mL for PINP, respectively. When measured with Serum Crosslaps® ELISA, Microtitre-plate based ELISA, Metra BAP EIA, and UniQ® PINP RIA, the reference intervals were 0.177-0.862ng/mL for sCTX, 22.6-95.7nmol BCE/mmol creatinine for uNTX/Cr, 14.8-38.8U/L for bone ALP, and 19.5-75.2ng/mL for PINP, respectively. The clinical interpretation of the BTMs of a subject should be based on comparison with a BTM reference interval, measured with the same assay method.

PubMed Disclaimer

Publication types

LinkOut - more resources