Energy expenditure estimate by heart-rate monitor and a portable electromagnetic coils system
- PMID: 22349175
- DOI: 10.1123/ijsnem.22.2.117
Energy expenditure estimate by heart-rate monitor and a portable electromagnetic coils system
Abstract
The aim of this article was to compare 2 portable devices (a heart-rate monitor and an electromagnetic-coil system) that evaluate 2 different physiological parameters--heart rate (HR) and ventilation (VE)--with the objective of estimating energy expenditure (EE). The authors set out to prove that VE is a more pertinent setting than HR to estimate EE during light to moderate activities (sitting and standing at rest and walking at 4, 5, and 6 km/hr). Eleven healthy men were recruited to take part in this study (27.6 ± 5.4 yr, 73.7 ± 9.7 kg). The authors determined the relationships between HR and EE and between VE and EE during light to moderate activities. They compared EE measured by indirect calorimetry (EEREF) with EE estimated by HR monitor (EEHR) and EE estimated by electromagnetic coils (EEMAG) in upright sitting and standing positions and during walking exercises. They compared EEREF with EEHR and EEMAG. The results showed no significant difference between the values of EEREF and EEMAG. However, they showed several significant differences between the values of EEREF and EEHR (for standing at rest and walking at 5 and 6 km/hr). These results showed that the electromagnetic-coil system seems to be more accurate than the HR monitor to estimate EE at rest and during exercise. Taking into consideration these results, it would be interesting to associate the parameters VE and HR to estimate EE. Furthermore, a new version of the electromagnetic-coil device was recently developed and provides the possibility to perform measurement under daily life conditions.
Similar articles
-
A new method to estimate energy expenditure from abdominal and rib cage distances.Eur J Appl Physiol. 2011 Nov;111(11):2823-35. doi: 10.1007/s00421-011-1900-9. Epub 2011 Mar 18. Eur J Appl Physiol. 2011. PMID: 21416146 Clinical Trial.
-
Accuracy of an infrared LED device to measure heart rate and energy expenditure during rest and exercise.J Sports Sci. 2011 Dec;29(15):1645-53. doi: 10.1080/02640414.2011.609899. Epub 2011 Oct 13. J Sports Sci. 2011. PMID: 21995327
-
Validity of the simultaneous heart rate-motion sensor technique for measuring energy expenditure.Med Sci Sports Exerc. 2002 May;34(5):888-94. doi: 10.1097/00005768-200205000-00025. Med Sci Sports Exerc. 2002. PMID: 11984311
-
A review of the evidence for the use of ventilation as a surrogate measure of energy expenditure.JPEN J Parenter Enteral Nutr. 2014 Nov;38(8):926-38. doi: 10.1177/0148607114530432. Epub 2014 Apr 17. JPEN J Parenter Enteral Nutr. 2014. PMID: 24743390 Review.
-
Heart rate measurements as an index of energy expenditure and energy balance in ruminants: a review.J Anim Sci. 2007 May;85(5):1213-27. doi: 10.2527/jas.2006-298. Epub 2007 Jan 15. J Anim Sci. 2007. PMID: 17224466 Review.
Cited by
-
Fusion of Heart Rate, Respiration and Motion Measurements from a Wearable Sensor System to Enhance Energy Expenditure Estimation.Sensors (Basel). 2018 Sep 14;18(9):3092. doi: 10.3390/s18093092. Sensors (Basel). 2018. PMID: 30223429 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources