Visualization of irrigation fluid flow and calculation of its velocity distribution in the anterior chamber by particle image velocimetry
- PMID: 22350059
- DOI: 10.1007/s00417-012-1953-4
Visualization of irrigation fluid flow and calculation of its velocity distribution in the anterior chamber by particle image velocimetry
Abstract
Purpose: To visualize irrigation fluid flow and calculate its velocity distribution in the anterior chamber during phacoemulsification by particle image velocimetry.
Methods: Porcine eyes were fixed in a glass chamber filled with balanced salt solution. An ultrasound handpiece was fixed to the glass chamber, and its tip was inserted into the anterior chamber through a corneal incision. Irrigation fluid was mixed with fluorescein-labeled liposomes as tracer particles. During phacoemulsification without ultrasound, a sheet-like Nd-YAG pulsed laser beam was emitted and moved from the iris plane to the top of the cornea continuously. Images of illuminated liposomes in the anterior chamber were captured at short intervals with a CCD camera, and the velocity distribution of irrigation fluid flow was calculated by particle image velocimetry.
Results: By particle image velocimetry, the flow velocity distribution could be calculated in any plane of the anterior chamber. Dynamic flow of the irrigation fluid, ejected from the tip of the ultrasound handpiece and returned to an aspiration port, was visualized clearly in the anterior chamber. The maximum flow velocity in the anterior chamber was 342 ± 131 mm/s.
Conclusions: Particle image velocimetry enabled the visualization of irrigation fluid flow and quantification of its velocity distribution in different planes of the anterior chamber during cataract surgery. These data are essential for evaluating the safety and efficacy of new surgical settings and devices during phacoemulsification.
Similar articles
-
Simulation of flow field during irrigation/aspiration in phacoemulsification using computational fluid dynamics.J Cataract Refract Surg. 2011 Aug;37(8):1530-8. doi: 10.1016/j.jcrs.2011.02.026. J Cataract Refract Surg. 2011. PMID: 21782098
-
Measuring rectilinear flow within the anterior chamber in phacoemulsification procedures.J Cataract Refract Surg. 2004 Aug;30(8):1759-67. doi: 10.1016/j.jcrs.2003.12.035. J Cataract Refract Surg. 2004. PMID: 15313304
-
Bead-flow pattern: quantitation of fluid movement during torsional and longitudinal phacoemulsification.J Cataract Refract Surg. 2010 Jun;36(6):1018-23. doi: 10.1016/j.jcrs.2009.12.028. J Cataract Refract Surg. 2010. PMID: 20494776
-
Free radical development in phacoemulsification cataract surgery.J Nippon Med Sch. 2005 Feb;72(1):4-12. doi: 10.1272/jnms.72.4. J Nippon Med Sch. 2005. PMID: 15834202 Review.
-
Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows.Front Physiol. 2022 Apr 29;13:886675. doi: 10.3389/fphys.2022.886675. eCollection 2022. Front Physiol. 2022. PMID: 35574441 Free PMC article. Review.
Cited by
-
Comparison of the Residual Amount of an Ophthalmic Viscosurgical Device Among Different Types of Intraocular Lens Implants in vitro.Clin Ophthalmol. 2024 Apr 20;18:1083-1091. doi: 10.2147/OPTH.S458348. eCollection 2024. Clin Ophthalmol. 2024. PMID: 38659426 Free PMC article.
-
Experimental research on intraocular aqueous flow by PIV method.Biomed Eng Online. 2013 Oct 21;12:108. doi: 10.1186/1475-925X-12-108. Biomed Eng Online. 2013. PMID: 24138704 Free PMC article.
-
Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model.BMC Ophthalmol. 2014 Nov 7;14:129. doi: 10.1186/1471-2415-14-129. BMC Ophthalmol. 2014. PMID: 25376934 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical