Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Sep;28(3):223-6.
doi: 10.1203/00006450-199009000-00013.

Reversal of venous blood flow with atrial tachycardia and hydrops in fetal sheep

Affiliations

Reversal of venous blood flow with atrial tachycardia and hydrops in fetal sheep

A L Gest et al. Pediatr Res. 1990 Sep.

Abstract

The purpose of this project was to characterize the reversal of blood flow in the proximal inferior vena cava (IVC) seen in fetal sheep with pacing-induced atrial tachycardia and hydrops. We successfully operated on seven pregnant ewes at 118-130 d gestation to attach ECG and pacing wires, insert vascular catheters, and place Doppler flow probes around the common aortic trunk and the IVC. We also performed two-dimensional and Doppler ultrasonographic exams at baseline, after initiation of pacing, and daily thereafter. All fetuses developed hydrops. Ultrasonographic appearance of ascites and pleural effusion occurred within 4 h in four fetuses and within 48 h in all fetuses. Atrial pacing did not affect arterial pH or arterial O2 tension, but arterial CO2 tension increased by a small amount. Mean IVC pressure increased 75%, whereas mean aortic pressure remained the same. Concentrations of plasma protein and albumin and the hematocrit did not change with atrial pacing. Doppler ultrasound examination and Doppler IVC flow tracings showed that flow reversal began immediately with atrial pacing and disappeared immediately with cessation of pacing. Reversed flow was 21% of forward flow. Inspection of simultaneous recordings of ECG, Doppler aortic and IVC flows, and aortic and IVC pressure tracings revealed that the reversed blood flow occurred in diastole in conjunction with atrial contraction and, therefore, could not be due to tricuspid insufficiency. Our findings of increased venous pressure and reversed venous blood flow suggest that ventricular function is impaired and further suggest that oxygen supply to the ventricles may not be sufficient for the increased demand.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources