Transvenous cardiac implantable electronic devices and hemodialysis catheters: recommendations to curtail a potentially lethal combination
- PMID: 22353033
- DOI: 10.1111/j.1525-139X.2012.01053.x
Transvenous cardiac implantable electronic devices and hemodialysis catheters: recommendations to curtail a potentially lethal combination
Abstract
Abnormal renal function is an independent risk factor for cardiac implantable electronic device (CIED) infection. The risk of CIED infection increases as the degree of renal dysfunction worsens with the highest risk observed in patients with stage V chronic kidney disease. A significant portion of these patients use a tunneled hemodialysis catheter (TDC) for dialysis therapy. These devices are associated with very high rates of catheter-related bacteremia (1.6-5.5 episodes of bacteremia per 1000 catheter days), and have been known to cause infection of CIED indwelling in the bloodstream. In this context, the cardiac device is exposed to the risk of infection due to the presence of renal failure and episodes of bacteremia related to TDCs. Both increase the risk of CIED infection. Once infected, a cardiac rhythm device carries a marked increase in morbidity and mortality. In this context, the combination of a TDC and a CIED indwelling in the bloodstream becomes a potentially deadly combination. Recent data have emphasized that epicardial CIED implantation reduces cardiac device infection in TDC patients. This report highlights the risk of CIED infection in renal patients, presents TDC's contribution to the cardiac device infection, and suggests recommendations to minimize the risk of CIED infection in chronic hemodialysis patients dialyzing with a TDC.
© 2012 Wiley Periodicals, Inc.
Similar articles
-
Epicardial cardiac rhythm devices for dialysis patients: minimizing the risk of infection and preserving central veins.Semin Dial. 2012 Jan-Feb;25(1):88-94. doi: 10.1111/j.1525-139X.2010.00757.x. Epub 2010 Aug 27. Semin Dial. 2012. PMID: 20807391
-
Contamination of transvenous pacemaker leads due to tunneled hemodialysis catheter infection: a report of 2 cases.Am J Kidney Dis. 2010 Jun;55(6):1097-101. doi: 10.1053/j.ajkd.2010.01.009. Epub 2010 Apr 3. Am J Kidney Dis. 2010. PMID: 20363542
-
Cardiovascular implantable electronic device infection in patients with Staphylococcus aureus bacteremia.Pacing Clin Electrophysiol. 2010 Apr;33(4):407-13. doi: 10.1111/j.1540-8159.2009.02565.x. Epub 2009 Sep 30. Pacing Clin Electrophysiol. 2010. PMID: 19793360
-
Management of bacteremia in patients living with cardiovascular implantable electronic devices.Heart Rhythm. 2016 Nov;13(11):2247-2252. doi: 10.1016/j.hrthm.2016.08.029. Epub 2016 Aug 19. Heart Rhythm. 2016. PMID: 27546815 Review.
-
Contemporary management of cardiovascular implantable electronic device infections.Expert Rev Anti Infect Ther. 2010 Jul;8(7):831-9. doi: 10.1586/eri.10.54. Expert Rev Anti Infect Ther. 2010. PMID: 20586567 Review.
Cited by
-
Pacemaker leads as a potential source of problems in patients who might need a central venous access port.Cardiovasc Diagn Ther. 2023 Dec 15;13(6):1068-1079. doi: 10.21037/cdt-23-104. Epub 2023 Oct 27. Cardiovasc Diagn Ther. 2023. PMID: 38162103 Free PMC article.
-
Do Implantable Cardioverter-Defibrillators Prevent Sudden Cardiac Death in End-Stage Renal Disease Patients on Dialysis?J Clin Med. 2024 Feb 19;13(4):1176. doi: 10.3390/jcm13041176. J Clin Med. 2024. PMID: 38398488 Free PMC article. Review.
-
How does a CIED presence influence chances and safety of haemodialysis access? Conclusions from over 3000 thoracic venografies.Clin Physiol Funct Imaging. 2023 Jan;43(1):47-57. doi: 10.1111/cpf.12792. Epub 2022 Oct 28. Clin Physiol Funct Imaging. 2023. PMID: 36251514 Free PMC article.
-
Subcutaneous versus Transvenous Implantable Cardioverter Defibrillator in Patients with End-Stage Renal Disease Requiring Dialysis: Extended Long-Term Retrospective Multicenter Follow-Up.J Pers Med. 2024 Aug 17;14(8):870. doi: 10.3390/jpm14080870. J Pers Med. 2024. PMID: 39202061 Free PMC article.
-
Cardiac Implantable Electronic Devices in Hemodialysis and Chronic Kidney Disease Patients-An Experience-Based Narrative Review.J Clin Med. 2021 Apr 17;10(8):1745. doi: 10.3390/jcm10081745. J Clin Med. 2021. PMID: 33920553 Free PMC article. Review.
Publication types