Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Sep;34(3):237-45.
doi: 10.1007/s10840-011-9661-2. Epub 2012 Feb 23.

Electrocardiographic left ventricular hypertrophy predicts arrhythmia and mortality in patients with ischemic cardiomyopathy

Affiliations

Electrocardiographic left ventricular hypertrophy predicts arrhythmia and mortality in patients with ischemic cardiomyopathy

Seth R Bender et al. J Interv Card Electrophysiol. 2012 Sep.

Abstract

Purpose: The relatively low incidence of device-treated ventricular arrhythmias in patients with ischemic cardiomyopathy (ICM) who receive implantable cardioverter defibrillators (ICDs) for primary prevention makes improved risk stratification of ICM patients a priority. Although Cornell product (CP) ECG left ventricular hypertrophy (LVH) has been associated with increased mortality in hypertensive patients and population-based studies, whether CP LVH can improve risk stratification of high-risk ICM patients is unclear. The aim of this study is to examine if electrocardiographic LVH predicts mortality and incident ventricular arrhythmia in patients with ICM.

Methods: All-cause mortality was examined in 317 patients with ICM and a history of non-sustained ventricular tachycardia (VT) who underwent electrophysiology testing. Incident VT and ventricular fibrillation (VF) were assessed in ICD recipients (n = 186). ECG LVH was defined by CP criteria: [(R (aVL) + S (V3)) + 6 mm in women] × QRS duration >2,440 mm ms.

Results: During 3 years of follow-up, mortality was 20% (64 of 317) and death or incident VT or VF occurred in 35% of ICD recipients. CP LVH was associated with significantly greater 3-year mortality (28% vs 15%, p = 0.015) and 3-year mortality or incident VT/VF in ICD patients (48% vs 35%, p = 0.011). In Cox multivariate models, CP LVH was an independent predictor of mortality in all patients (hazard ratio (HR) 1.81, 95% confidence interval (CI) 1.11-2.97, p = 0.020) and of the composite endpoint of mortality or incident ventricular arrhythmia in ICD patients (HR 1.82, 95% CI 1.12-3.00, p = 0.016).

Conclusions: ECG LVH using CP criteria may enhance risk stratification in high-risk patients with ICM.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Med. 1983 Sep 26;75(3A):4-11 - PubMed
    1. Circulation. 1998 Jun 2;97(21):2129-35 - PubMed
    1. Circulation. 1994 Oct;90(4):1786-93 - PubMed
    1. Ann Noninvasive Electrocardiol. 2001 Apr;6(2):107-16 - PubMed
    1. Circulation. 2001 Jul 24;104(4):436-41 - PubMed

Publication types

MeSH terms

LinkOut - more resources