[Respiratory insufficiency in patients with myasthenia gravis]
- PMID: 2235711
[Respiratory insufficiency in patients with myasthenia gravis]
Abstract
We evaluated 20 patients who required prolonged mechanical ventilation for respiratory failure associated with myasthenia gravis. All 20 patients survived and were weaned from the ventilator after 3 to 14 days (mean 6.5 days) of respiratory support. Progressing bulbar symptoms and respiratory infection were the most frequent causes of the myasthenic crisis. During a period of assisted mechanical ventilation, anticholinesterase medication was interrupted and the patients were treated with steroids and antibiotics. Plasmapheresis may be considered in the management of myasthenic crisis.
Similar articles
-
Mechanical ventilation for respiratory failure in myasthenia gravis. Two-year experience with 22 patients.Mayo Clin Proc. 1983 Sep;58(9):597-602. Mayo Clin Proc. 1983. PMID: 6887975
-
Myasthenia gravis: management of myasthenic crisis and perioperative care.Semin Neurol. 2004 Mar;24(1):75-81. doi: 10.1055/s-2004-829595. Semin Neurol. 2004. PMID: 15229794 Review.
-
Intensive respiratory care in patients with myasthenic crisis.Neurol India. 2002 Sep;50(3):348-51. Neurol India. 2002. PMID: 12391468
-
Plasmapheresis in the treatment of ventilator-dependent myasthenia gravis patients. Report of four cases.Chest. 1984 Jun;85(6):739-43. doi: 10.1378/chest.85.6.739. Chest. 1984. PMID: 6723382
-
Respiratory failure associated with myasthenia gravis.J Ky Med Assoc. 1991 Apr;89(4):169-73. J Ky Med Assoc. 1991. PMID: 2040830 Review.